Rinnai 26i, HD50i Dip Switch Setting, Dip Switch Positions Explained, Nat Gas, Combustion Normal

Models: 26i, HD50i

1 40
Download 40 pages 13.22 Kb
Page 31
Image 31
DIP SWITCH SETTING

DIP SWITCH SETTING

Dip Switch Positions Explained

OFF ON SW1

 

 

 

 

1

-

Computer Programming

 

 

2

-

Temperature

 

 

3

-

Temperature

 

 

4

-

Temperature

 

 

5

-

Temperature

 

 

6

-

Temperature

 

 

7

-

Combustion

 

 

 

8

-

Combustion

OFF ON SW2

-

Gas Type

 

 

 

1

 

 

2

-

Not in Use

 

 

3

-

Computer Programming

 

 

 

4

-

Not in Use

LEGEND:

Black Section indicates position of dip switch.

OFF ON

 

OFF ON

 

 

 

 

 

OFF ON

Dip Switches Explained

GAS TYPE

LPG

OFF ON SW2

1 off

2

3

4

NAT GAS

OFF ON SW2

1 on

2

3

4

COMBUSTION

NORMAL

OFF ON SW1 7 off 8 off

FORCED LOW

COMPUTER PROGRAMMING

OFF ON SW1

1 Computer programming

2Switches and Not in Use

3Switches are always in the

4OFF position for the

5Infinity 26i and HD50i.

6

7

8

OFF ON SW2 1 2 3 4

31

OFF ON SW1

Dip Switch Positions Explained 7 on

8 off

FORCED HIGH

OFF ON SW1 7

8 on

Page 31
Image 31
Rinnai 26i, HD50i Dip Switch Setting, Dip Switch Positions Explained, Dip Switches Explained GAS TYPE LPG, Nat Gas