Operating Instructions

FOR YOUR SAFETY READ BEFORE OPERATING

If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.

A.This appliance does not have a pilot. It is equipped with an ignition device which automatically lights the burner. Do not try to light the burner by hand.

B.BEFORE OPERATING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electric switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

C.Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, do not try to repair it, call a qualified service technician. Force or attempted repair may result in a fire or explosion.

D.Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.

OPERATING INSTRUCTIONS

1.STOP! Read the safety information above.

2.Set the thermostat to lowest setting.

3.Turn off all electric power to the appliance using the ON/OFF button.

4.This appliance is equipped with an ignition device which automatically lights the burner. Do not try to light the burner by hand.

5.Locate the manual gas valve on the side of the heater. Turn the manual valve

clockwise to the full OFF position.

Manual Valve

CLOSE OPEN

6.Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell

gas, STOP! Follow “B” in the safety information above. If you don,t smell gas, go to the next step.

7.Turn the manual gas valve counterclockwise to the

full ON position.

8.Turn on all electric power to the appliance using the ON/OFF button.

9.Set the thermostat to desired setting.

10.Open a hot water tap. If the appliance will not operate, follow the instructions “To Turn Off Gas To Appliance” and call your service technician or gas supplier. See manual for additional information.

TO TURN OFF GAS TO APPLIANCE

1.Turn off all electric power to the appliance using the ON/OFF button.

2.Set the thermostat to lowest setting.

3.Locate the manual gas valve on the side of the heater. Turn the manual valve clockwise to the full

OFF position.

VA Series Outdoor LS Manual

33

Page 33
Image 33
Rinnai R63LSe, R98LSe, R94LSe, R75LSe installation manual Operating Instructions, For Your Safety Read Before Operating

R75LSe, R94LSe, R63LSe, R98LSe specifications

The Rinnai R94LSe, R98LSe, R75LSe, and R63LSe are part of Rinnai's premier line of tankless water heaters, designed to provide on-demand hot water efficiently and sustainably. Each model caters to different household needs while offering advanced technologies and features.

The R94LSe boasts a maximum output of 9.4 GPM, making it ideal for larger households. It features a digital display that provides real-time information on temperature settings and performance. The R94LSe incorporates Circ-Logic technology, allowing users to set a schedule for hot water demands, ensuring instant access to hot water when needed. This model also employs a self-diagnostic system, which continually monitors performance and alerts users to any maintenance needs, helping extend the unit's lifespan.

The R98LSe is another powerful option with a maximum output of 9.8 GPM, perfect for homes with multiple bathrooms. It includes a remote control and a user-friendly interface, enhancing user experience. The R98LSe also features a unique indoor venting system, significantly reducing installation constraints, and is designed with energy efficiency in mind. This model's ultra-efficient heat exchanger provides consistent temperature control while minimizing energy consumption, fulfilling the growing demand for eco-friendly products.

For those seeking slightly less capacity, the R75LSe has a maximum output of 7.5 GPM, making it suitable for medium-sized homes. Similar to its counterparts, it utilizes Rinnai’s advanced technology to optimize energy usage. The R75LSe features an integrated freezing protection system and a compact design that allows for flexible installation options both indoors and outdoors.

The R63LSe is the smallest of the lineup, with an output of 6.3 GPM, making it ideal for smaller homes or apartments. Despite its compact size, it does not compromise on efficiency, offering advanced control options and energy-saving features. It includes a digital display for easy monitoring and can be equipped with an optional recirculation pump to enhance water availability.

Overall, the Rinnai R94LSe, R98LSe, R75LSe, and R63LSe models offer a range of capabilities suitable for various household sizes and hot water demands. These tankless water heaters exemplify innovation with their energy-efficient designs, advanced technologies, and ease of use, marking Rinnai as a leader in the market for reliable hot water solutions.