Rinnai R63LSe Temperature Ranges, Setting the Sound Volume Voice Prompt, Setting the Clock, Model

Models: R75LSe R94LSe R63LSe R98LSe

1 40
Download 40 pages 45.26 Kb
Page 9
Image 9
Temperature Ranges

Temperature Ranges

This water heater will attempt to provide hot water at the temperature even when the water flow is varied or when more than 1 tap is in use. The water heater can deliver water at only one temperature setting at a time. The available temperatures for a given model are provided below.

Model

 

 

 

Temperature Settings Available (ºF)

 

 

 

*

*

*

R63LSe

98

100

102

104

106

108

110

115

120

125

130

135

140

150

160

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

R75LSe

98

100

102

104

106

108

110

115

120

125

130

135

140

150

160

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

R94LSe

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

R98LSe

98

100

102

104

106

108

110

115

120

125

130

135

140

150

160

185

R98LSe-ASME

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Temp in Celsius ºC

37

38

39

40

41

42

43

46

49

52

54

57

60

66

71

85

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*These settings require the MCC-91 controller. When the MCC-91 controller is connected, these higher temperature are available on all controller models in the system.

If a space heating application requires higher than 140º F then a mixing valve shall be installed to temper the water temperature to 140º F or less for domestic use.

Suggested temperatures are

Kitchen

120 ºF (49º C)

Shower

98º - 110º F (37º - 43º C)

Bath Fill

102º - 110º F (39º - 43º C)

These temperatures are suggestions only.

Temperature lower than 98º F (37º C) can be obtained at the tap by mixing with cold water.

To change the temperature scale from Celsius to Fahrenheit or vice versa, press and hold the “On/Off” button for 5 seconds while the water heater is OFF.

Setting the Sound Volume (Voice Prompt)

MC-100VPress the “Function” button to adjust the voice prompt volume. The default sound volume is set to Medium. Each subsequent press of the Model or Temperature Settings Available (ºF) button cycles through the volume levels in the order below.

Medium Volume

Off Volume

BC-100VPress the “Sound Vol.” button to adjust the voice prompt volume. The default sound volume is set to Medium. Each subsequent press of the button cycles through the volume levels in the order below.

Off Sound

(default)

High Volume

(beep)

 

(no beep)

Low Volume

Setting the Clock

MC-100VPress the “Function” button twice within 10 seconds to set the clock. Press the Setting the Sound Volume (Voice Prompt) or Setting the Clock button to reach the desired time. The clock on the BC-100V automatically shows

the time which has been set on the MC-100V.

VA Series Outdoor LS Manual

9

Page 9
Image 9
Rinnai R63LSe, R98LSe, R94LSe, R75LSe Temperature Ranges, Setting the Sound Volume Voice Prompt, Setting the Clock, Model