Error Code Table

Error

Fault

Remedy

 

 

 

14

Thermal Fuse

Check gas type of unit and ensure it matches gas type being used.

 

 

Check for restrictions in air flow around unit and vent terminal.

 

 

Check for low water flow in a circulating system causing short-cycling.

 

 

Ensure dip switches are set to the proper position.

 

 

Check for foreign materials in combustion chamber and/or exhaust piping.

 

 

Check heat exchanger for cracks and/or separations.

 

 

Check heat exchanger surface for hot spots which indicate blockage due to scale build

 

 

up. Refer to instructions in manual for flushing heat exchanger.

 

 

Measure resistance of safety circuit.

 

 

Ensure high fire and low fire manifold pressure is correct.

 

 

Check for improper conversion of product.

16

Over Temperature

Check for restrictions in air flow around unit and vent terminal.

 

Warning

Check for low water flow in a circulating system causing short-cycling.

 

 

Check for foreign materials in combustion chamber and/or exhaust piping.

 

 

Check for clogged heat exchanger.

32

Outgoing Water

Check sensor wiring for damage.

 

Temperature Sensor

Measure resistance of sensor.

 

Fault

Clean sensor of scale build up.

 

 

Replace sensor.

33

Heat Exchanger

Check sensor wiring for damage.

 

Outgoing Temperature

Measure resistance of sensor.

 

Sensor Fault

Clean sensor of scale build up.

 

 

Replace sensor.

34

Combustion Air

Check for restrictions in air flow around unit and vent terminal.

 

Temperature Sensor

Check sensor wiring for damage.

 

Fault

Measure resistance of sensor.

 

 

Clean sensor of scale build up.

 

 

Ensure fan blade is tight on motor shaft and is in good condition.

 

 

Replace sensor.

52

Modulating Solenoid

Check modulating gas solenoid valve wiring harness for loose or damage terminals.

 

Valve Signal Abnormal

Measure resistance of valve coil.

61

Combustion Fan

Ensure fan will turn freely.

 

Failure

Check wiring harness to motor for damaged and/or loose connections.

 

 

Measure resistance of motor winding.

65

Water Flow Servo

If blank screen is present on remote control then the flow control has shorted out.

 

Faulty

Unplug flow control. If remote lights up and unit starts operating then replace flow

 

(does not stop flow properly)

control assembly.

71

SV0, SV1, SV2, and

Check wiring harness to all solenoids for damage and/or loose connections.

 

SV3 Solenoid Valve

Measure resistance of each solenoid valve coil.

 

Circuit Fault

 

72

Flame Sensing Device

Ensure flame rod is touching flame when unit fires.

 

Fault

Check all wiring to flame rod for damage.

 

 

Remove flame rod and check for carbon build-up; clean with sand paper.

 

 

Check inside burner chamber for any foreign material blocking flame at flame rod.

 

 

Measure micro amp output of sensor circuit with flame present.

 

 

Replace flame rod.

LC

Scale Build-up in Heat

Flush heat exchanger. Refer to instructions in manual.

 

Exchanger (when

Replace heat exchanger.

 

checking maintenance

 

 

code history “00” is

 

 

substituted for “LC”)

 

No

Nothing happens when

Clean inlet water supply filter.

code

water flow is activated.

On new installations ensure hot and cold water lines are not reversed.

 

 

Check for bleed over. Isolate unit from building by turning off hot water line to building.

 

 

Isolate the circulating system if present. Open your pressure relief valve; if unit

 

 

fires, there is bleed over in your plumbing.

 

 

Ensure you have at least the minimum flow rate required to fire unit.

 

 

Ensure turbine spins freely.

 

 

Measure the resistance of the water flow control sensor.

 

 

Check for DC shorts at components

 

 

 

14

VA Series Outdoor LS Manual

Page 14
Image 14
Rinnai R94LSe, R98LSe, R63LSe, R75LSe installation manual Code

R75LSe, R94LSe, R63LSe, R98LSe specifications

The Rinnai R94LSe, R98LSe, R75LSe, and R63LSe are part of Rinnai's premier line of tankless water heaters, designed to provide on-demand hot water efficiently and sustainably. Each model caters to different household needs while offering advanced technologies and features.

The R94LSe boasts a maximum output of 9.4 GPM, making it ideal for larger households. It features a digital display that provides real-time information on temperature settings and performance. The R94LSe incorporates Circ-Logic technology, allowing users to set a schedule for hot water demands, ensuring instant access to hot water when needed. This model also employs a self-diagnostic system, which continually monitors performance and alerts users to any maintenance needs, helping extend the unit's lifespan.

The R98LSe is another powerful option with a maximum output of 9.8 GPM, perfect for homes with multiple bathrooms. It includes a remote control and a user-friendly interface, enhancing user experience. The R98LSe also features a unique indoor venting system, significantly reducing installation constraints, and is designed with energy efficiency in mind. This model's ultra-efficient heat exchanger provides consistent temperature control while minimizing energy consumption, fulfilling the growing demand for eco-friendly products.

For those seeking slightly less capacity, the R75LSe has a maximum output of 7.5 GPM, making it suitable for medium-sized homes. Similar to its counterparts, it utilizes Rinnai’s advanced technology to optimize energy usage. The R75LSe features an integrated freezing protection system and a compact design that allows for flexible installation options both indoors and outdoors.

The R63LSe is the smallest of the lineup, with an output of 6.3 GPM, making it ideal for smaller homes or apartments. Despite its compact size, it does not compromise on efficiency, offering advanced control options and energy-saving features. It includes a digital display for easy monitoring and can be equipped with an optional recirculation pump to enhance water availability.

Overall, the Rinnai R94LSe, R98LSe, R75LSe, and R63LSe models offer a range of capabilities suitable for various household sizes and hot water demands. These tankless water heaters exemplify innovation with their energy-efficient designs, advanced technologies, and ease of use, marking Rinnai as a leader in the market for reliable hot water solutions.