Rinnai R94LSe Clearances from Appliance, Attachment of the Water Heater, to side, to floor/ground

Models: R75LSe R94LSe R63LSe R98LSe

1 40
Download 40 pages 45.26 Kb
Page 18
Image 18
Clearances from Appliance

Clearances from Appliance

 

to

to Non-

 

 

Combustibles

Combustibles

 

 

 

 

 

Top of

12 inches

2 inches

 

Heater

(305 mm)

(51 mm)

 

 

 

 

 

Back of

0 (zero)

0 (zero)

 

Heater

 

 

 

 

 

 

 

 

Front of

24 inches

24 inches

 

Heater

(610mm)

(610 mm)

to side

Sides of

6 inches

1/2 inch

 

Heater

(152 mm)

(13 mm)

 

 

 

 

 

Floor/

12 inches

2 inches

 

Ground

(305 mm)

(51 mm)

 

 

 

 

 

The clearance for servicing is 24 inches in front of the water heater

to floor/ground

to top

to front

Attachment of the Water Heater

1.Identify the installation location and confirm that the installation will meet all required clearances.

2.Securely attach the water heater to the wall using any of the holes in the wall installation brackets which are at the top and bottom of the water heater. Ensure that the attachment strength is sufficient to support the weight. Refer to the weight of the water heater in the Specifications section.

wall installation

brackets

18

VA Series Outdoor LS Manual

Page 18
Image 18
Rinnai R94LSe, R98LSe Clearances from Appliance, Attachment of the Water Heater, to side, to floor/ground, to top to front