Rinnai R98LSe, R63LSe, R94LSe Recommended Piping for Circulation Systems, Rinnai Water Heater

Models: R75LSe R94LSe R63LSe R98LSe

1 40
Download 40 pages 45.26 Kb
Page 24
Image 24
Recommended Piping for Circulation Systems

Recommended Piping for Circulation Systems

Notes:

PLEASE NOTE FOR RESIDENTIAL AND COMMERCIAL APPLICATIONS, THIS PIPING ARRANGEMENT MAINTAINSFULL WARRANTY

For this application:

Pump should be controlled by an Aquastat, Timer or Combination Aquastat and Timer.

Pump to be sized to maintain circulation loop temperature.

A minimum of 3 GPM flow is recommended for the circulation system.

The pump should be sized to overcome the pressure loss through the Rinnai water heater, supply and return plumbing. Refer - ence the Rinnai Hot Water System Design Manual, Pump Sizing for Circulation.

Pump to be of bronze or stainless construc - tion.

Rinnai

Water Heater

Rinnai

QTY

Equipment List

Rinnai

1

Water Heaters

 

RIK-KIT (Optional)

1

(3/4" Fittings Include:

 

2

Unions, 2 Ball Valves,

 

2

Drain Valves and

 

1

Pressure Relief Valve.)

 

3/4" Gas Connection

 

Gas Supply

Minimum 3/4" Cold Water Supply Line

IMPORTANT: Connect the building return line to the hot water supply line as close as possible to the Rinnai Water Heater.

Tank Water Heater to be Sized for Heat Loss of Circulation Loop.

Electric Water

Heater

Building Supply

Building

Fixtures

Expansion Tank

 

KEY

3/4" Ball Valve

Pressure Regulator

 

3/4" Union

Circulating Pump

Check Valve

Boiler Drain Valve

Pressure Relief Valve

S Solenoid Valve

This is not an engineered drawing, it is intended only as a guide and not as a replacement for professionally engineered project drawings. This drawing is not intended to describe a complete system, it is up to the contractor/engineer to determine the necessary components for and configuration of the particular system being installed. The drawing does not imply compliance with local building code requirements. It is the engineer/contractor responsiblity to ensure the installation is in accordance with all local building codes. Confer with local building officials before installation.

24

VA Series Outdoor LS Manual

Page 24
Image 24
Rinnai R98LSe, R63LSe, R94LSe, R75LSe Recommended Piping for Circulation Systems, Rinnai Water Heater, For this application