Rinnai R75LSe Remote Controller Installation, Mounting on the wall, Control Cable, Cable Clamp

Models: R75LSe R94LSe R63LSe R98LSe

1 40
Download 40 pages 45.26 Kb
Page 31
Image 31
Mounting on the wall

Remote Controller Installation

Mounting on the wall

1.

Determine a suitable location for the

 

controller.

2.

Make three holes in the wall as shown.

Outline of Remote

3.

Run the cable between the controller and the

 

Rinnai water heater or the controller and

 

another controller.

4.

Remove the face plate from the remote

 

controller using a screw driver.

5.

Connect the cable to the remote controller.

6.

Mount the controller to the wall using the

 

holes drilled in step 2.

securing screw

wiring hole

securing screwREMOTE CONTROL

1-21/32"

3-5/16"

Connecting to the R75LSe, R94LSe, R98LSe, and R98LSe-ASME

7.Disconnect the power from the Rinnai water heater.

8.Remove the cover of the Rinnai water heater.

9.Remove the plastic cover from the PCB and electrical connections.

10.Thread the cable through the access hole at the base of the unit and connect the wires to the controller terminals on the right hand side bottom of the PCB.

11.Secure the controller cable using the clamp provided.

12.Replace plastic cover over PCB and then replace the cover of the Rinnai water heater.

REMOTE CONTROL

CONNECTION TERMINALS

REMOTE

CONTROL CABLE

CABLE CLAMP

VA Series Outdoor LS Manual

31

Page 31
Image 31
Rinnai R75LSe, R98LSe Remote Controller Installation, Mounting on the wall, Remote Control Connection Terminals Remote