Remote Controller Installation
Connecting to the R63LSe
7.Disconnect the power from the water heater.
8.Remove a screw on the Quick Cable Connector. (Fig. 1)
9.To access the cable screws rotate the Quick Cable Connector 90º (Fig. 2)
10.Insert wire cable through the Cable Access Hole (Fig. 2)
11.Loosen the clamp screw and secure wire cable with clamp. The clamp is in the box with the remote controller. Make sure the length of the wire is long enough. There should be no tension in the wire. (Fig. 3)
12.Loosen 2 cable screws on the terminals for controls and connect the cable. You cannot connect more than 2 cables at a time. When connecting more than 2 cables, connect them in parallel. (Fig. 4)
13.Install the Quick Cable Connector with 1 screw. (Fig. 5)
Quick Cable
Connector
Fig.1
Cable Access
Hole
Fig.2
Clamp
Clamp Screw
Fig.3
Cable Screw |
Fig.4
Fig.5