Copying selected measures ofa pattern
You can copy selected measures of a part or pattern. Unlike
copying an entire pattern, settings such as instrument and
part volume etc. will not be copied; only the performance
data will be copied.
fig.07-15
Procedure
1. Press [PATTERN]-[F3 (EDIT)]-[F2 (COPY)]-[F3 (MEAS)].
The “COPY PATTERN MEASURE” page will appear.
2. In location A of the screen, select the data you wish to
copy. Use [CURSOR] to move the cursor to the various
settings.
From the left, the display will indicate the pattern, part, first
measure, and last measure.
3. Use [INC/DEC] or the VALUE dial to make the settings.
4. In location B of the screen, select the copy destination.
Use [CURSOR] to move to the various settings.
The display indicates the pattern number, track, and starting
measure.
* Beginning at the first measure which you specify here, the num-
ber of measures that the copy source occupies will be overwrit-
ten.
5. Use [INC/DEC] or the VALUE dial to make the settings.
6. Press [F4 (COPY)]
A confirmation display will appear.
7. Press [F4 (EXEC)] and the specified portion of perfor-
mance data will be copied. (Press [F1 (CANCEL)] to
return to the previous page without executing the opera-
tion.)
Clearing a pattern
This operation deletes ALL data from a pattern, returning all
parameters (time signature,length, tempo) to their default
values.
fig.07-15ae
Procedure
1. Press [PATTERN]-[F3 (EDIT)]-[F3 (CLEAR)].
The “CLEAR PATTERN” page will appear.
2. Use [INC/DEC] or the VALUE dial to select the pattern
number that you wish to clear.
3. Press [F4 (CLEAR)]
A confirmation display will appear.
4. Press [F4 (EXEC)] and the contents of the selected pat-
tern will be erased. (Press [F1 (CANCEL)] to return to the
previous page without executing the operation.)
Clearing selected measures ofa pattern
This operation lets you clear (delete) selected measures in a
pattern. After executing CLEAR, the length of the pattern
will become shorter.
fig.07-15b
Procedure
1. Press [PATTERN]-[F3 (EDIT)]-[F3 (CLEAR)]-[F3 (MEAS)].
The “CLEAR PATTERN MEASURE” page will appear.
2. Select the pattern and measures that you wish to clear.
Use [CURSOR] to move the cursor to the various set-
tings.
From the left, the display indicates the pattern, the first mea-
sure, and the last measure.
123456
123456
Src
Dst

A

B

123456
1
(Part settings to their default values.)
123456
1234
Chapter 6. Sequencer
105
Chapter 1
Chapter 2
Chapter 3
Chapter 4
Chapter 5
Chapter 6
Chapter 7
Chapter 8
Chapter 9
Chapter 10