44

Chapter 5. Trigger Settings [TRIGGER]

To be sure the TD-20 accurately receives signals sent from the
pads, select the

trigger type

(the type of pads being used) for
each trigger input.

Trigger Type

A

trigger type

is a group of trigger settings with values
optimally adjusted for a particular pad. Indications such as
“KD120,” “PD125,” or “VH12,” etc. in the above display
correspond to this. When you select a trigger type for a
connected pad, each of the parameters is set to the most
appropriate values for that pad, allowing you to play it
without encountering problems with the settings. Only when
factors unrelated to the selection of the proper trigger type
prevent you from getting good results in performance should
you fine-tune the individual parameters for the pad you are
using.

Trigger Bank

Trigger Banks

allow you to store the 15 trigger settings as a
single unit of information. The large number at the left edge of
the above display is the Trigger Bank number. Move the
cursor to this area to select the Trigger Bank.

1.

Press [TRIGGER] - [F1 (BANK)].

[TRIGGER] lights, and the “TRIGGER BANK” screen will
appear.

fig.05-TrigBank_70

2.

Press [CURSOR (left)] to move the cursor to the
Trigger Bank number.
3.
Use [+/-] or [VALUE] to select the Trigger Bank.
4.
Press [CURSOR (right)] to move the cursor to a
trigger type.
5.
Strike the pad you wish to set.

The cursor will move to the trigger type for the struck
pad.
You can also select by using [CURSOR] or [TRIG
SELECT].

6.

Use [+/-] or [VALUE] to select the trigger type.

* When you select the trigger type, the trigger parameters (except
the crosstalk cancel parameters) are automatically set to the
most efficient values for each pad. Make settings for the
parameter as needed.
* When 3Way Trigger (p. 50) is set to ON, “RD CTRL” is
displayed for the trigger type for TRIGGER INPUT 11 EDGE.
It cannot be changed.
* Brush sweep and Cross Stick can be used only SNARE.
* Each playing method can be used with the instruments
corresponding to it (p. 95).

Selecting the Pad Type [F1

(BANK)]

Trigger Type Used Model

PD125 PD-125
PD120 PD-120
PD105 PD-105
PD100 PD-100
PD85 PD-85, PD-80R, PD-80
PD9 PD-9
PD8 PD-8
PD7 PD-7
PD6 PD-6
KD120 KD-120
KD85 KD-85, KD-80
KD8 KD-8
KD7 KD-7
CY15R CY-15R
CY12RC CY-12R/C
CY14C CY-14C
CY8 CY-8
CY6 CY-6
CY12H CY-12H
VH12 VH-12
VH11 VH-11
PAD1 When using a non-Roland pad
PAD2
RT7K RT-7K
RT5S RT-5S
RT3T RT-3T

Trigger Inputs and Pad/Playing

Methods corresponding chart

Trigger In-
put
Dual Trigger
Mesh Pad
Positional
Sensing
Rim Shot
Nuance

KICK x x x
SNARE o o o
TOM 1–4 o x o
HI-HAT x x x
CRASH 1, 2 x x x
RIDE x o x
EDGE x x x
AUX 1–4 o x o
TD-20_Ref_e.book 44 ページ 2005年5月25日 水曜日 午前9時49分