Rose electronic MAN-V8 manual Appendix F. Typematic rate, Typematic Command, Typematic Rate

Models: MAN-V8

1 36
Download 36 pages 78 b
Page 34
Image 34
Appendix F. Typematic rate

Appendix F. Typematic rate

Typematic Command

Press the left <Ctrl> key, type “A”, enter the typematic value (1-3 digit) followed by <Enter>.

The typematic value is determined from the following tables using the equation: Typematic Value = Rate value + Delay Value. Pick the desired rate in keys/sec. and the delay in milliseconds from tables below. Add the Rate Value and the Delay Value. The sum of these values is the typematic value to enter.

For example to use a Rate of 16.0 keys/sec. and a 500 millisecond delay, the Rate value = 7 and the Delay value = 32. Add 7 + 32 = 39. To set a typematic value of 16, press the left <Ctrl> key, type “A”, enter 39, and then press Enter.

Typematic Rate

Rate

Rate

Rate

 

Rate

Rate

Rate

Rate

Rate

Keys/sec

Value

keys/sec

 

Value

Keys/sec

Value

Keys/sec

Value

30.0

0

15.0

 

8

7.5

16

3.7

24

26.7

1

13.3

 

9

6.7

17

3.3

25

24.0

2

12.0

 

10

6.0

18

3.0

26

21.8

3

10.9

 

11

5.5

19

2.7

27

20.0

4

10.0

 

12

5.0

20

2.5

29

18.5

5

9.2

 

13

4.6

21

2.3

28

17.1

6

8.6

 

14

4.3

22

2.1

30

16.0

7

8.0

 

15

4.0

23

2.0

31

 

 

 

Typematic Delay

 

 

 

 

 

 

 

 

 

 

 

 

Delay*

Delay

Delay*

 

Delay

Delay*

Delay

Delay*

Delay

 

Value

 

 

Value

 

Value

 

Value

250

0

500

 

32

750

64

1000

96

* Delay in milliseconds