ULTRA ATA/133 PCI RAID Card RC200

User Manual

 

 

 

For Auto Setup

1.As the BIOS boots press F3 when prompted to enter the RAID BIOS.

2.Press F2 to create a RAID set.

3.Press F3 to create a Mirrored-Striped set.

4.Press A to Auto configure.

5.Press Y to accept the configuration.

6.Press ESC to reboot.

7.Continue with FDISK and FORMAT steps as if you were installing a conventional hard drive.

Rebuilding a Failed RAID 0+1 Set

The steps below will guide you in rebuilding a failed Mirror-Stripe set.

1.Replace the failed drive with one of identical size or of large capacity.

Note: It is recommended to replace the bad drive with an identical drive, or with a drive of the same make. In all cases, the replacement drive must be of equal or larger capacity then the bad drive.

2.Start the computer and during boot press F3, when prompted, to enter the RAID BIOS.

3.Press F3 to assign a Spare drive.

4.Press the number corresponding to the new drive.

5.When asked Are You Sure?, Press Y to accept.

6.Press ESC to exit the RAID BIOS and reboot the computer.

7.Continue with FDISK and FORMAT steps as if you were installing a conventional hard drive.

13