GET Commands

What are GET Commands?

They are commands for outputting TXD such as adjustment data from the internal microcomputer of the plasma display to a PC.

Adjustment data, etc., is output in ASCII code.

NOTE: Command names are given inside brackets < >.

Data output format

STX (o2hex)

Data

Data

....

Checksum

ETX (03hex)

NOTE:

1)GET commands will be invalid when no ID NO. Set is assigned to the set.

2)GET commands will be invalid when wildcard (*) is used in the ID No. Set when sending the command.

1) <GST> (GET STATUS)

Order

Data Contents

 

Size

 

 

 

Remarks

 

 

1

Display data

 

3byte

See below

 

 

 

 

2

Power data

 

3byte

See below (The third character is sub input)

 

 

3

Input function data (main)

 

3byte

Input data when GST is received (INPUT1 to 5 is displayed as IN1 to 5)

4

Input function data (sub)

 

3byte

Sub input data when GST is received Note 3

 

 

 

 

 

 

(INPUT1 to 5 is displayed as IN1 to 5)

 

 

5

Screen size data

 

1byte

See below

 

 

 

 

6

2-screen display

 

1byte

0: OFF (1 screen)

1: 2-SCREEN

2: PinP (lower right)

 

 

 

 

3: PinP (upper right)

4: PinP (upper left)

5: PinP (lower left)

 

 

 

 

6: PoutP

 

 

 

 

7

FUNCTIONAL LOCK data

 

1byte

0: LOCK OFF

1: BUTTONS LOCK

2: IR LOCK

 

 

 

 

3: IR & BUTTONS LOCK

4: MEMORY LOCK

8

Dummy Data

 

3byte

(3-digit number)

 

 

 

 

9

Temperature data 2

 

3byte

(Internal temperature: Reference value) oC Note 1

10

Temperature data 3

 

3byte

(Internal temperature: Reference value) oC Note 1

11

Serial

 

15byte

 

 

 

 

 

 

12

Dummy data

 

3byte

(3-digit number)

 

 

 

 

13

Dummy data

 

3byte

 

 

 

 

 

 

14

HOURMETER

 

5byte

Display the time.

 

 

 

 

15

Checksum

 

2byte

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Display data

First character

 

Generation data: 4 (fixed)

 

 

 

 

Second character

Inch data: 4 (43 inches), 5 (50 inch)

 

 

 

 

 

 

 

 

 

 

 

Third character

 

Destination data: M (fixed)

 

 

 

Power Data

First character

 

Power state & signal state

 

 

 

 

 

 

 

PN (POWER ON & normal signal input)

 

 

 

 

 

 

 

PL (POWER ON & no input)

 

 

 

 

Second character

PO (POWER ON & OUT OF RANGE signal input)

 

 

 

SN (Normal standby)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SW (Standby by AUTO POWER OFF)

 

 

 

 

 

 

 

SS (Standby by SD or PD)

 

 

 

 

 

 

 

Sub input signal state during multi-screen display

 

 

 

Third character

 

N (Normal signal input)

L (No input)

 

 

 

 

 

 

 

O (OUT OF RANGE signal input)

 

 

 

Screen size data

First character

 

(0) Pix by Pix or Letterbox, (1) STD (4:3), (2) ANAMPHC 16:9, (3) Letterbox

 

 

 

(1080i), (4) Cinema, (5) Virtualwide, (8) Letterbox (1035i), (9) Underscan

 

 

 

 

 

 

 

NOTE 1) During standby and immediately after POWER ON, the proper value is not output. In this case, wait a moment after POWER ON, then get the data. The temperature data is output as a reference (the values are not guaranteed values). Normally, refer to temperature data 3.

NOTE 2) During standby and during 1-screen display, dummy data (symbol) is output.

NOTE 3) During standby and during 1-screen display the values stored in memory for the product are output.

28

Page 29
Image 29
Runco CW-50MC manual GET Commands