Runco CW-50MC manual What are GET Commands?, Gst Get Status

Models: CW-50MC

1 36
Download 36 pages 17.18 Kb
Page 29
Image 29
GET Commands

GET Commands

What are GET Commands?

They are commands for outputting TXD such as adjustment data from the internal microcomputer of the plasma display to a PC.

Adjustment data, etc., is output in ASCII code.

NOTE: Command names are given inside brackets < >.

Data output format

STX (o2hex)

Data

Data

....

Checksum

ETX (03hex)

NOTE:

1)GET commands will be invalid when no ID NO. Set is assigned to the set.

2)GET commands will be invalid when wildcard (*) is used in the ID No. Set when sending the command.

1) <GST> (GET STATUS)

Order

Data Contents

 

Size

 

 

 

Remarks

 

 

1

Display data

 

3byte

See below

 

 

 

 

2

Power data

 

3byte

See below (The third character is sub input)

 

 

3

Input function data (main)

 

3byte

Input data when GST is received (INPUT1 to 5 is displayed as IN1 to 5)

4

Input function data (sub)

 

3byte

Sub input data when GST is received Note 3

 

 

 

 

 

 

(INPUT1 to 5 is displayed as IN1 to 5)

 

 

5

Screen size data

 

1byte

See below

 

 

 

 

6

2-screen display

 

1byte

0: OFF (1 screen)

1: 2-SCREEN

2: PinP (lower right)

 

 

 

 

3: PinP (upper right)

4: PinP (upper left)

5: PinP (lower left)

 

 

 

 

6: PoutP

 

 

 

 

7

FUNCTIONAL LOCK data

 

1byte

0: LOCK OFF

1: BUTTONS LOCK

2: IR LOCK

 

 

 

 

3: IR & BUTTONS LOCK

4: MEMORY LOCK

8

Dummy Data

 

3byte

(3-digit number)

 

 

 

 

9

Temperature data 2

 

3byte

(Internal temperature: Reference value) oC Note 1

10

Temperature data 3

 

3byte

(Internal temperature: Reference value) oC Note 1

11

Serial

 

15byte

 

 

 

 

 

 

12

Dummy data

 

3byte

(3-digit number)

 

 

 

 

13

Dummy data

 

3byte

 

 

 

 

 

 

14

HOURMETER

 

5byte

Display the time.

 

 

 

 

15

Checksum

 

2byte

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Display data

First character

 

Generation data: 4 (fixed)

 

 

 

 

Second character

Inch data: 4 (43 inches), 5 (50 inch)

 

 

 

 

 

 

 

 

 

 

 

Third character

 

Destination data: M (fixed)

 

 

 

Power Data

First character

 

Power state & signal state

 

 

 

 

 

 

 

PN (POWER ON & normal signal input)

 

 

 

 

 

 

 

PL (POWER ON & no input)

 

 

 

 

Second character

PO (POWER ON & OUT OF RANGE signal input)

 

 

 

SN (Normal standby)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SW (Standby by AUTO POWER OFF)

 

 

 

 

 

 

 

SS (Standby by SD or PD)

 

 

 

 

 

 

 

Sub input signal state during multi-screen display

 

 

 

Third character

 

N (Normal signal input)

L (No input)

 

 

 

 

 

 

 

O (OUT OF RANGE signal input)

 

 

 

Screen size data

First character

 

(0) Pix by Pix or Letterbox, (1) STD (4:3), (2) ANAMPHC 16:9, (3) Letterbox

 

 

 

(1080i), (4) Cinema, (5) Virtualwide, (8) Letterbox (1035i), (9) Underscan

 

 

 

 

 

 

 

NOTE 1) During standby and immediately after POWER ON, the proper value is not output. In this case, wait a moment after POWER ON, then get the data. The temperature data is output as a reference (the values are not guaranteed values). Normally, refer to temperature data 3.

NOTE 2) During standby and during 1-screen display, dummy data (symbol) is output.

NOTE 3) During standby and during 1-screen display the values stored in memory for the product are output.