Maintenance and Troubleshooting

Table 5-1. Troubleshooting Chart (continued)

Symptom

 

Possible Cause(s)

Solution

 

 

 

Colors in the image are

• The Red/Pr, Green/Y or

• Ensure that the source

swapped; for example, reds

 

Blue/Pb outputs from the

outputs are connected to

appear blue or vice versa.

 

source are connected to

the correct Crystal Series

 

 

the wrong inputs on the

LCD Display input.

 

 

Crystal Series LCD

 

 

 

Display.

 

 

 

 

RGB-HD images appear

• Clock and Phase settings

• Manually adjust Clock and

“noisy.”

 

need adjustment.

Phase settings, or perform

 

 

 

an Auto-Adjust (refer to PC

 

 

 

Mode Adjust on

 

 

 

page 38).

 

 

 

 

“Out of range” appears

The resolution and

• Select a compatible

on-screen.

 

frequency of the video

resolution and vertical

 

 

card in the computer are

frequency (refer to

 

 

not compatible with the

Computer Signal

 

 

Crystal Series LCD

Compatibility on

 

 

Display.

page 61).

 

 

 

 

The image is too large or too

Image size needs

• Adjust the image size (refer

small.

 

adjusting.

to PC Mode Adjust on

 

 

 

page 38).

 

 

 

Poor broadcast sound quality.

• The sound quality of a

• Use the MTS/SAP button

 

 

stereo broadcast may be

on the remote control to

 

 

unstable in an area with a

select mono.

 

 

weak signal.

 

 

 

 

 

50

Runco CX-40HD/CX-46HD Owner’s Operating Manual

Page 60
Image 60
Runco CX-46HD, CX-40HD manual Computer Signal