6. Serial Communications

To interface the Crystal Series LCD Display with a home theater automation/control system or a PC running terminal emulation software, connect it to your control system or PC as shown in Figure 3-11.

Configure the RS-232 controller or PC serial port as follows: no parity, 8 data bits, 1 stop bit and no flow control. Set the baud rate to match that of the Crystal Series LCD Display RS-232 port; the default baud rate is 115200.

6.1

RS-232 Connection and Port Configuration

Commands are in ASCII format and are not case-sensitive.

A carriage return is not required after a command.

When you send a valid command, the Crystal Series LCD Display executes it and acknowledges it with a right-bracket character (]) followed by the four-digit numeric code you sent; for example, ]0002.

When you send an invalid command (one followed by values outside the valid range for that command), the Crystal Series LCD Display ignores it and returns >MAX or <MIN instead of the four-digit code.

When you send an unrecognized/misspelled command, the Crystal Series LCD Display ignores it and returns -N/Ainstead of the four-digit code.

Table 6-1lists the RS-232 command set.

Table 6-1. Serial Commands

Command

 

 

Description

 

 

 

 

 

 

[

 

S3A

 

0###

Set audio volume to ### ( = 000-100)

 

 

 

 

Example: [S3A0075 sets volume to 75

 

 

 

 

 

 

[

 

+3A

 

 

Audio volume up

 

 

 

 

 

 

[

 

-3A

 

 

Audio volume down

 

 

 

 

 

 

[

 

S3E

 

000#

Audio mute (speakers/headphones)

 

 

 

 

 

0

= not muted, 1 = muted

 

 

 

 

Example: [S3E0001 mutes the audio output

 

 

 

 

 

 

[

 

S4A

 

000#

Main input selection

 

 

 

 

 

0

= TV

 

 

 

 

 

1

= Input1

 

 

 

 

 

2

= Input2

 

 

 

 

 

3

= Input3

 

 

 

 

 

4

= Input4

 

 

 

 

 

6

= RGB

 

 

 

 

 

8

= HDMI1

 

 

 

 

 

9

= HDMI2

 

 

 

 

 

Example:

[S4A0006 selects RGB

 

 

 

 

 

 

 

6.2

Serial Command Syntax

Runco CX-40HD/CX-46HD Owner’s Operating Manual

51

Page 61
Image 61