Sampo DR-S0426 manual RS-485 control protocol

Models: DR-S0426

1 29
Download 29 pages 1.84 Kb
Page 24
Image 24

9RS-485 control protocol

Data format

Data: 1 Byte / Parity: None / Start bit: 1 / Baud: 9600

Totally 3 bytes in data frame:

 

1.

Byte=0x10

:Broadcasting DVR

 

Byte=0x80+ID Number

:Remote Control DVR (ID number range: 5~21)

2.

Byte=Refer to below table

:Command for each key string

3.

Byte=First byte plus Second byte

:Command for confirm checksum

Part

Label

Command

 

 

 

5

REC

0x21

 

 

 

6

CH1

0x11

7

CH2

0x12

8

CH3

0x13

 

 

 

9

CH4

0x14

 

 

 

10

CHALL

0x15

 

 

 

11

COPY

NONE

 

 

 

12

RFAST

0x3A

 

 

 

13

STOP

0x51

 

 

 

14

PAUSE

0x3D

 

 

 

15

FFAST

0x3E

 

 

 

16

PLAY

0x52

 

 

 

17

UPRT

0x31

 

 

 

18

DNLT

0x32

 

 

 

19

MENU

0x20

 

 

 

20

LEFT

0x33

 

 

 

21

SELECT (ENTER)

0x35

 

 

 

22

Page 24
Image 24
Sampo DR-S0426 manual RS-485 control protocol