4. Electrical Characteristics
4.1 TFT LCD Module
The connector for display data & timing signal should be connected.
Ta = 25°C ± 2 °C
Item |
| Symbol | Min. | Typ. | Max. | Unit | Note |
Voltage of Power Supply | VDD | 4.5 | 5.0 | 5.5 | V | (1) | |
Current | (a) Black |
| - | 1000 | - | mA |
|
|
|
|
|
|
|
| |
of Power | (b) White | IDD | - | 1250 | - | mA | (2),(3) |
Supply |
|
|
|
|
|
|
|
(c) |
| - | 1500 | 2000 | mA |
| |
|
|
| |||||
|
|
|
|
|
|
|
|
Vsync Frequency | fV | - | 60 | - | Hz |
| |
Hsync Frequency | fH | 44 | 47.3 | - | kHz |
| |
Main Frequency | fDCLK | 65 | 75 | 82 | MHz |
| |
Rush Current | IRUSH | - | - | 4 | A | (4) |
Note (1) The ripple voltage should be controlled under 10% of VDD.
(2) fV=60Hz, fDCLK = 75MHz, VDD = 5.0V, DC Current.
(3) Power dissipation check pattern (LCD Module only)
a) Black Pattern | b) White Pattern |
| c) | ||||||||||||||||||||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
(4) Measurement Conditions |
| ||
100% |
| VDD | |
| |||
90% |
|
| |
10% |
|
| |
GND |
|
| |
|
|
|
TRUSH=470㎲
Rush Current IRUSH can be measured when TRUSH. is 470㎲.