3. Optical Characteristics

The optical characteristics should be measured in a dark room or equivalent. Measuring equipment : TOPCON BM-7,SPECTRORADIOMETER SR-3

 

 

(Ta = 25 ± 2°C, VDD=5V,fv= 60Hz, fDCLK=75MHz, IL = 7.0mArms(Hot) )

Item

 

Symbol

Condition

Min.

 

Typ.

Max.

Unit

Note

 

Contrast Ratio

C/R

 

800

 

1200

-

 

(3)

 

(Center of screen)

 

 

 

SR-3

 

 

 

 

 

 

 

 

 

Response

Rising

Tr

 

-

 

8

12

 

(5)

 

 

 

 

 

 

 

 

msec

 

Falling

Tf

 

-

 

6

10

 

Time

 

 

BM-7

 

G-to-G

Tg

 

-

 

8

-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Luminance of White

Y

Normal

400

 

450

-

cd/m2

(6)

 

(Center of screen)

L

θL,R=0

 

 

 

 

 

SR-3

 

 

Red

Rx

θU,D=0

 

 

0.641

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Ry

Viewing

 

 

0.331

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Gx

 

 

0.279

 

 

 

 

 

Green

Angle

 

 

 

 

 

 

Color

 

 

 

 

 

 

 

 

 

Gy

 

TYP.

 

0.594

TYP.

 

(7),(8)

 

 

 

 

 

 

Chromaticity

 

 

 

-0.03

 

 

+0.03

 

SR-3

 

 

Bx

 

 

0.144

 

 

(CIE 1931)

Blue

 

 

 

 

 

By

 

 

 

0.064

 

 

 

 

 

 

 

 

 

 

 

 

 

 

White

Wx

 

 

 

0.280

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Wy

 

 

 

0.290

 

 

 

 

 

 

 

 

 

 

 

 

 

Color Gamut

-

 

-

 

72

-

%

(7)

 

 

 

SR-3

 

 

 

 

 

 

 

 

 

 

 

Color Temperature

-

 

-

 

10000

-

K

(7)

 

 

 

SR-3

 

 

 

 

 

 

 

 

 

 

 

 

Hor.

θL

 

75

 

89

-

 

 

 

Viewing

θR

C/R10

75

 

89

-

Degree

(8)

 

 

 

 

Angle

Ver.

θU

75

 

89

-

SR-3

 

 

 

 

 

 

θD

 

75

 

89

-

 

 

 

 

 

 

 

 

 

 

Brightness Uniformity

Buni

 

-

 

-

25

%

(4)

 

(9 Points)

 

 

SR-3

 

Note (1) Test Equipment Setup

The measurement should be executed in a stable, windless and dark room between 40min and 60min after lighting the back light at the given temperature for stabilization of the back light. This should be measured in the center of screen.

Single lamp current : 7.0mA(Hot)Environment condition : Ta = 25 ± 2 °C

 

MODEL

LTI320W2-L14

Doc. No

05-000-G-060331

Page

7 / 28