(5)Definition of test point 5mm

5mm

1

2

 

5

LCD Module (Active)

3

4

T should be less than 10 (T = TOPR – TMAX )

TOPR

: Temperature of the center of the glass surface (Test point 5)

T1~ T4 : Temperature of each edge of the glass surface

TMAX

: The highest temperature of the glass surface

2. Application information for I.D. (Information Display)

-Generally large-sized LCD modules are designed for TV applications. Accordingly, a long-term display like in PID application, can cause uneven display including image retention. To optimize module's lifetime and function, several operating usages are required.

1.Normal operating condition

-Temperature: 20 ± 15

-Humidity: 65 ± 20 %

-Display pattern: dynamic pattern

Note) Long-term static display can cause image retention.

2.Operating usages under abnormal condition1) a. Ambient condition

-Well-ventilated place is recommended to set up ID system. b. Power and screen save

-Periodical power-off or screen save2) is needed after long-term display.

3.Operating usages to protect against image retention due to long-term static display a. Suitable operating time: under 18 hours a day.

b. Static information display recommended to use with moving image.

-Cycling display between 5 minutes' information display and 10 seconds' moving image. c. Background and character (image) color change

-Use different colors for background and character, respectively.

-Change colors themselves periodically.

d. Avoid combination of background and character with large different luminance.

1)Abnormal condition just means conditions except normal condition.

2)Black image or moving image is strongly recommended as a screen save.

4. Lifetime in this spec. is guaranteed only when ID is used according to operating usages.

 

MODEL

LTI320W2-L14

Doc. No

05-000-G-060331

Page

6 / 28