1. Absolute Maximum Ratings

If the condition exceeds maximum ratings, it can cause malfunction or unrecoverable damage to the device.

Item

 

SymbolMin.Max.UnitNote
Power Supply Voltage

VDD

GND-0.5

6.5

V

(1)

Storage temperature

TSTG

-20

60

(2)
Glass surface

 

Center

TOPR

0

50

(2),(5)
temperature

 

 

 

 

 

 

 

T. Uniformity

T

-

10

 

(Operation)

 

 

 

 

 

 

 

 

 

Shock ( non - operating )

Snop

-

50

G

(3)

Vibration ( non - operating )

Vnop

-

1.5

G

(4)

Note (1) Ta= 25 ± 2 °C

(2)Temperature and relative humidity range are shown in the figure below.

a.90 % RH Max. (Ta 39 °C)

b.Maximum wet-bulb temperature at 39 °C or less. (Ta 39 °C)

c.No condensation

(3)11ms, sine wave, one time for ±X, ±Y, ±Z axis

(4)10-300 Hz, Sweep rate 10min, 30min for X,Y,Z axis

Fig. Temperature and Relative humidity range

 

MODEL

LTI320W2-L14

Doc. No

05-000-G-060331

Page

5 / 28