1. Absolute Maximum Ratings
If the condition exceeds maximum ratings, it can cause malfunction or unrecoverable damage to the device.
Item |
| Symbol | Min. | Max. | Unit | Note | |
Power Supply Voltage | VDD | 6.5 | V | (1) | |||
Storage temperature | TSTG | 60 | ℃ | (2) | |||
Glass surface |
| Center | TOPR | 0 | 50 | ℃ | (2),(5) |
temperature |
|
|
|
|
|
| |
| T. Uniformity | △T | - | 10 |
| ||
(Operation) |
| ℃ |
| ||||
|
|
|
|
|
|
| |
Shock ( non - operating ) | Snop | - | 50 | G | (3) | ||
Vibration ( non - operating ) | Vnop | - | 1.5 | G | (4) |
Note (1) Ta= 25 ± 2 °C
(2)Temperature and relative humidity range are shown in the figure below.
a.90 % RH Max. (Ta ≤ 39 °C)
b.Maximum
c.No condensation
(3)11ms, sine wave, one time for ±X, ±Y, ±Z axis
(4)
| MODEL | Doc. No | Page | 5 / 28 |
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|