Each attribute data structure is assigned an attribute ID. Any non-zero value in the attribute ID number indicates an active attribute. Valid values for this byte are found from 0x01 through 0xff. The attribute defined for Spinpoint M9T are as follows:

Table 8-17 SMART Attribute Data List

Attribute ID

Definition

Monitor

1

Raw read error rate

Errors during read operations.

3

Spin up time

Spin up time in millisecond

4

Spindle motor on count

On/off count.

5

Number of Auto Reassign sectors

Reassigned sector count.

7

Seek error rate

Errors during seek operations.

8

Seek time performance

Off-line random seek time

9

Drive run time.

How long drive works.

10

Spin up retry count

Retry count

12

Power cycle count

Total power cycles.

194

Temperature.

Pre amp die temperature

195

ECC on the fly

ECC count for read operation

196

Re-allocate sector event

Read scan uncorrectable read error

197

Pending sector count

Off-line scan pending sectors

198

Uncorrectable sector count

Off-line scan uncorrectable sectors.

199

UDMA CRC error rate

CRC Errors during UDMA transfer

200

Write error rate

Errors during write operations.

201

Soft error rate

Soft errors during read operations.

Off-line data collection status

The value of the off-line data collection status byte defines the current status of the off-line activities of the device. Table6-15 lists the values and their respective definitions.

 

 

Table 8-18 Off-line Data Collection Status Values

 

 

 

 

 

 

 

 

 

 

Value

Definition

 

 

 

 

00h or 80h

Off-line data collection activity was never started.

 

 

 

 

 

 

 

 

 

 

01h

Reserved

 

 

 

 

 

 

 

 

 

02h or 82h

Off-line data collection activity was completed without error.

 

 

 

 

 

 

 

 

 

03h

Reserved

 

 

 

 

 

 

 

 

 

04h or 84h

Off-line data collection Activity was suspended by an interrupting command from host

 

 

 

 

 

 

 

 

05h or 85h

Off-line data collection Activity was aborted by an interrupting command from host

 

 

 

 

 

 

 

 

06h or 86h

Off-line data collection Activity was aborted by the device with a fatal error.

 

 

 

 

 

 

 

 

 

07h-3Fh

Reserved

 

 

 

 

 

 

 

 

 

 

40h-7Fh

Vendor specific

 

 

 

 

 

 

 

 

 

 

81h

Reserved

 

 

 

 

 

 

 

 

 

 

83h

Reserved

 

 

 

 

 

 

 

 

 

 

87h-BFh

Reserved

 

 

 

 

 

 

 

 

 

 

C0h-FFh

Vendor specific

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Spinpoint M9T Product Manual REV 1.0

68

 

 

Page 73
Image 73
Samsung M9T manual Smart Attribute Data List, Off-line Data Collection Status Values