Samsung ML-1700 Self Diagnostic Mode, Code, Description, Main Motor Operating System

Models: ML-1700

1 120
Download 120 pages 49.52 Kb
Page 54
Image 54
6.1.3 Self Diagnostic Mode

ALIGNMENT & ADJUSTMENTS

6.1.3 Self Diagnostic Mode

If Error code occurs due to malfunction of the printer, perform Self Diagnostic Mode to solve the problem.

The printer works only in the self-test mode to solve the malfunction problem.

To enter the self-test mode, turn the power on pressing the buttons of [Down], [Shift] and [Stop] at the same time.

Release the button within 2 or 3 seconds if 78 shows in the DCU. If 00 shows in the DCU, press the button [Up] or [Shift] to select the self+test , and press the button of [Enter] to operate. To stop, press the button of [shift] and [Enter] together.

Code

Description

 

 

00

Main Motor Operating System

 

Only the main motor is in operation.

 

 

01

Main High Voltage On(THV-)

 

-1400 voltage output by MHV terminal.

 

Caution : High voltage probe should be used.

 

 

02

Transfer High Voltage(-)On(THV-)

 

-1000 voltage output by MHV terminal.

 

Caution : High voltage probe should be used.

 

 

03

Transfer High Voltage (+)Reference on (THV +)

 

+800 voltage output by MHV terminal.

 

Caution : High voltage probe should be used.

 

 

04

DEV/supply High Voltage : DEV/Supply High Voltage Test.

 

The left one of the three LEDs in the self-test panel is on when DEV high voltage Supply

 

high voltage output by each HV terminal(-500V). Press the [Up] button to switch the volt-

 

age. The middle and right one of the three LEDs are on and -650 voltage output by DEV

 

HV terminal.

 

Caution : High voltage probe should be used.

 

 

05

LSU Operating System

 

The scanning motor of LSU is in operation, the right LED of the three buttons on. Press

 

the [Up] button to Check LD. LD is functioning and the middle button is on. If the LD is

 

normal, all LEDs are on.

 

 

06

Pickup clutch on

 

The Solenoid in the printer is in operation. To stop the operation, Press the button [shift]

 

and [Enter] together.

 

 