Samsung ML-1700 specifications Fusing, Heat Lamp Method, Q-PID Method, Error, Description

Models: ML-1700

1 120
Download 120 pages 49.52 Kb
Page 38
Image 38
4.6.4 Fusing

S U M M A RY OF PRO D U C T

4.6.4 Fusing

The temperature change of the heat roller’s surface is changed to the resistance value through the thermis- tor. By converting the voltage value, which impressed to the resistance, to the digital value through the AD converter, the temperature is decided. The AC power is controlled by comparing the target temperature to the value from the thermistor. If the value from the thermistor is out of the controlling range while controlling the fusing, the error stated in the table occurs. (For the domestic model, the Q-PID method has been applied.)

4.6.4.1 Heat Lamp Method

Error

Open heat error

Lower heat error

Description

When warming up, it has been lower than 68°C over 28 seconds

Standby:

It has been lower than 80°C over 10 seconds

Printing:

-2 consecutive pages: it has been lower than 145°C over 4 seconds.

-3 consecutive page; it has been 25°C lower

than the fixed fusing temperature over 4 seconds.

DCU

LED Displat

60All LED are blinking.

62All LED are blinking

Over heat error

It have been higher than 220°C over 3 seconds

68 All LED are blinking

 

 

 

4.6.4.2 Q-PID Method

Error

Open heat error

Lower heat error

Over heat error

Description

When preheating, it has been lower than 68°C over 15 seconds.

After finishing the preheating stage,

it has not reached 100°C (preheating stop temperature) during 15 seconds since the temperature is over 68°C.

Printing

1)When the main motor is on and after 0.92 second, it has not reached the 160°C during 20 seconds.

2)From the 2 consecutive pages, it has been 20°C lower than the fusing temperature over 4 seconds.

the error is not displayed immediately when it has been over 220°C over 3 seconds.

The temperature after the 3 seconds is checked. If it is over 240°C, it is error.

If the temperature has been higher than 220°C over 25 seconds, it is an error even through the temperature doesn’t reach 240°C.

DCU

LED Displat

60All LED are blinking

62All LED are blinking

68 All LED are blinking

Service Manual

Samsung Electronics

4-21

Page 38
Image 38