6. Technical point

3) The other water level data

unit:Khz

The water data unter each conditon

 

 

 

 

 

 

1st water supply (only preparation)

24.60

 

1st water supply level to washing tub

 

 

 

 

Overflow error

20.50

 

The water supplied reach 2/3 of door

 

 

 

 

Bubble

25.45

 

Bubble -detecting water level

detectingatwashing/rinse/dehydrating

 

 

 

 

Bubble detecting rinse water level

22.60

 

The water level which can detect bubbles

 

 

 

 

Water level which can open door

24.10

over

It is possible to open the door

 

 

 

Water level which can drive heater

24.50(3.5 )

Safety water level of wash heater

 

 

 

Water level which can reset the drain

24.50

 

The water level can be detected after 1st draining

 

 

 

 

If water level is 15KHZ below or 30 KHZ above , sensor-pressur is out of order so needs changing.