11
6. Technical point

3) The other water level data

If water level is 15KHZ below or 30 KHZ above , s ensor-pressur is out of order so needs changing.
The water data unter each conditon
1st water supply (only preparation) 24.60 1st water supply level to washing tub
Overflow error 20.50 The water supplied reach 2/3 of door
Bubble
detectingatwashing/rinse/dehydrating 25.45 Bubble -detecting water level
Bubble detecting rinse water level 22.60 The water level which can detect bubbles
Water level which can open door 24.10 over It is possible to open the door
Water level which can drive heater 24.50(3.5)Safety water level of wash heater
Water level which can reset the drain 24.50 The water level can be detected afte r 1st draining
unit:Khz