13
7. General Error Function
-If the same signal as the above table is detected for more than
5seconds, itis aPRESSURE S/W Error.
-When the error occurs, water drain pump will operate for 3 min. and
thenturn off the water drain pump.
Thenthe display shows fig.8 indicatinga pressure s/w error indicator.
8.A BNORMAL WATER TEMPERATURE ERROR
-In c asethe water temperature is 50C or more in Delicate and Wool
course.
-At the time of initial water supply, if the water temperature is not
appropriate,water starts to be drained andit is forced to be drained
for2 min when the abnormal frequency of 24.5KHz is detected.
-Display shows fig.9
-This error can be cleared by POWER S/W OFF.
9.WATER L EAKAGE ERROR (E9)
-Water Leakage error occures when water is drained naturally after
washingprogram starts.
10.Tacho Error
-This error occurs in case motor thaco is out of order or tacho siganals
inputtedare fewer than 2
- Display shows fig.11
- This error can be cleared by power s/w o ff
11.Motor Triac short Error
-This error occurs in case over 300 per 1 sec tacho signals are inputted
powerS/w should be off.
-fig.12 is diplayed.
- This error can be cleared by power s/w o ff
12.Thermistor error
-This error occurs, when Thermistor circuit is abnormal or the detected
electricalvolt is 0.2v below or 4.5v over
- fig. 13 is displayed
- This error can be cleared by power s/w o ff
fig. 8
fig. 9
fig. 10
fig. 11
fig. 12
fig. 13