5. Main function
4) Power-out compensation function
●If power is out on selected process, the process before power out is stored to EEPROM, once power is back the process before power out continues.
●When power is back, washing process starts from the process at the point of the power out, rinse/drain process starts from the initial process.
POWER-OUT COMPENSATION FUNCTION PROCESS
START | WASHING |
| POWER OUT |
SAVE DATA |
|
to EEPROM | POWER BACK |
MICOM RESTORE
READ DATA
(PROCESS+TIME) RESTART PROCESS
RINSE/DRAIN
START
SAVE DATA to EEPROM
RINSE/DRAIN
PROCESS
POWER OUT
POWER BACK
MICOM RESTORE
FINISH
5) Water heater Error function
①This function starts working, when the heater works abnormally.
(this function begins sensing the heater 1 minutes later, after the heater operating)
②The value of the initial thermistor(A1) is compared with that of the thermistor(A2) in 2 minutes
message is displayed on the panel.
③The value of the initial thermistor(A1) is compared with that of the thermistor(A2) in 2 minutes
led on" message is displayed on the panel.
④At this time heater, Error "course led 8ea on 30℃/60℃ led on" is displayed and all working process off
⑤The heater operating continues during heating hours, if washing hour is left over, the residual washing process keeps going without heating.