23
10. Designation of Main Components

10-1 Normal / Reverse Revolution of Motor and R. P. M. Control

10-2 Door safety Device

When Door is closed, door stay closed. if "set" is operated, power supplied to , wires have bymetal keep
the door closed, and electronical power flows between and make it operate.
+
-
89
510
Rotor
Stator coil
CW
+
-
89
5
5
10
Rotor
Stator coil
CCW
<Figure1> <Figure2>
12345678910
STATOR
WASHING MOTOR
TACHO
HIGH-SPEED
STATOR
PROTECTOR
MIDDLE-SPEED
ROTOR
(150 C)

H

(
±7%)
STATOR(51) ROTOR(8.9) TACHO(3.4) PROTECTOR(6.7) "H"(mm) Code-No. Remark
Resistance
value
2.08
1.99
38.8
039 DC31-00002E R1031
R831
R631
Rated
value 220~240V/50Hz