7. General Error Function

When an error occurs, this function starts to keep generating error melody sounds and displays error indicators as shown in the followings per corresponding error by blinking in 0.5sec interval until the error status is completely cleared out. In this case, all the driving devices are turned off until the error is cleared out.

 

 

○ : Light on

 

1. WATER SUPPLY ERROR

 

● : Light off

 

- Display shows such as fig. 1

 

 

 

- Water Supply Error occurs when water level frequency does not show

 

 

 

changes more than 100Hz or water is not supplied

 

 

 

up to the water level presetting for 20 min or more at the time of initial

 

 

 

water supply.

 

 

 

-The error status can be cleared by turning POWER S/W OFF and

 

 

 

resuming the POWER ON initial status.

fig. 1

 

 

 

2. WATER DRAIN ERROR

- Display shows such as fig.2

- In case the water level frequency is 24.5KHz or less in the initial phase of UNB-detecting cycle.

- Water Drain error can be cleared by turning POWER S/W OFF and resuming the POWER ON initial status.

fig. 2

3. OVER-FLOW ERROR

- Display shows such as fig.3

- Over-Flow error occurs when the water level is in abnormal operation. It can be cleared by turning POWER S/W OFF.

Water is drained prior to POWER S/W OFF and it is forced to be drained for 2 min if a frequency of more than 24.5 KHz is detected.

 

fig. 3

4. UNBALANCE ERROR

 

 

- Display shows such as fig4.

 

- Laundry load is unbalanced; loosen any tangled laundry.

 

- If only one item of clothing needs washing, such as a bathrobe or jeans,

 

the final spin result might be unsatisfactory and an error message will be

 

shown in the display panel such as fig 4..

 

 

- Unbalance error is cleared by POWER S/W OFF and by resuming the

fig. 4

POWER ON initial status.

 

5. WATER HEATER ERROR

 

- Display shows such as fig.5 or fig.6

 

- In case the water temperature rises by 7∞C or more in 1 min. or by 2∞C

 

less in 10 min after heating is started.

 

- It can be cleared by turning POWER S/W OFF.

fig. 5

 

 

fig. 6

6 DOOR OPEN ERROR

- Display shows such as fig.7

- Door Open error can be cleared by closing the door.

fig. 7

7. ASSí Y PRESSURE S/W ERROR

* Generated Frequency Signal of WATER LEVEL(W/L) S/W (KHz)

 

Level

Low Level

High Level

 

 

Abnormal W/L Frequency

30.00 KHz

15.00 KHz

 

 

 

 

 

 

12

Page 13