Impostazioni di terminazione RS-422A/RS-485

SW 501

Come illustrato nella mappa della struttura, quando il Controller e il modulo RS 422A/RS-485 sono connessi, le operazioni di terminazione debbono essere effettuate in base all’impedenza opposta dal cavo in ognuna delle uscite della linea di trasmissione, al fine di trasferire i segnali a lunga distanza controllando però la riflessione del segnale a bassa distanza.

Divisione

n < 128

Terminazione

SW1-ON

<RS-485 in semi-duplex>

Terminazione: utilizzare i numeri 1 e 2 PIN, selezionare ON e la procedura sarà terminata.

n < 128

IMPOSTAZIONI DI SELEZIONE

identificativo ricevitore

SW500-1 SW500-2

SW500-3

SW500-4 SW500-5 SW500-6 SW500-7

SW500-8

0

OFF

OFF

OFF

OFF

OFF

OFF

OFF

OFF

1

ON

OFF

OFF

OFF

OFF

OFF

OFF

OFF

2

OFF

ON

OFF

OFF

OFF

OFF

OFF

OFF

3

ON

ON

OFF

OFF

OFF

OFF

OFF

OFF

4

OFF

OFF

ON

OFF

OFF

OFF

OFF

OFF

5

ON

OFF

ON

OFF

OFF

OFF

OFF

OFF

6

OFF

ON

ON

OFF

OFF

OFF

OFF

OFF

7

ON

ON

ON

OFF

OFF

OFF

OFF

OFF

8

OFF

OFF

OFF

ON

OFF

OFF

OFF

OFF

9

ON

OFF

OFF

ON

OFF

OFF

OFF

OFF

10

OFF

ON

OFF

ON

OFF

OFF

OFF

OFF

11

ON

ON

OFF

ON

OFF

OFF

OFF

OFF

12

OFF

OFF

ON

ON

OFF

OFF

OFF

OFF

13

ON

OFF

ON

ON

OFF

OFF

OFF

OFF

14

OFF

ON

ON

ON

OFF

OFF

OFF

OFF

15

ON

ON

ON

ON

OFF

OFF

OFF

OFF

16

OFF

OFF

OFF

OFF

ON

OFF

OFF

OFF

17

ON

OFF

OFF

OFF

ON

OFF

OFF

OFF

18

OFF

ON

OFF

OFF

ON

OFF

OFF

OFF

19

ON

ON

OFF

OFF

ON

OFF

OFF

OFF

20

OFF

OFF

ON

OFF

ON

OFF

OFF

OFF

21

ON

OFF

ON

OFF

ON

OFF

OFF

OFF

22

OFF

ON

ON

OFF

ON

OFF

OFF

OFF

23

ON

ON

ON

OFF

ON

OFF

OFF

OFF

24

OFF

OFF

OFF

ON

ON

OFF

OFF

OFF

25

ON

OFF

OFF

ON

ON

OFF

OFF

OFF

26

OFF

ON

OFF

ON

ON

OFF

OFF

OFF

27

ON

ON

OFF

ON

ON

OFF

OFF

OFF

28

OFF

OFF

ON

ON

ON

OFF

OFF

OFF

29

ON

OFF

ON

ON

ON

OFF

OFF

OFF

30

OFF

ON

ON

ON

ON

OFF

OFF

OFF

31

ON

ON

ON

ON

ON

OFF

OFF

OFF

32

OFF

OFF

OFF

OFF

OFF

ON

OFF

OFF

33

ON

OFF

OFF

OFF

OFF

ON

OFF

OFF

34

OFF

ON

OFF

OFF

OFF

ON

OFF

OFF

35

ON

ON

OFF

OFF

OFF

ON

OFF

OFF

I

Divisione

Division SW1-ON SW2-ON

36

OFF

OFF

ON

OFF

OFF

ON

OFF

OFF

37

ON

OFF

ON

OFF

OFF

ON

OFF

OFF

38

OFF

ON

ON

OFF

OFF

ON

OFF

OFF

39

ON

ON

ON

OFF

OFF

ON

OFF

OFF

40

OFF

OFF

OFF

ON

OFF

ON

OFF

OFF

41

ON

OFF

OFF

ON

OFF

ON

OFF

OFF

42

OFF

ON

OFF

ON

OFF

ON

OFF

OFF

43

ON

ON

OFF

ON

OFF

ON

OFF

OFF

44

OFF

OFF

ON

ON

OFF

ON

OFF

OFF

45

ON

OFF

ON

ON

OFF

ON

OFF

OFF

<RS-422A/RS-485 in duplex>

46

OFF

ON

ON

ON

OFF

ON

OFF

OFF

47

ON

ON

ON

ON

OFF

ON

OFF

OFF

48

OFF

OFF

OFF

OFF

ON

ON

OFF

OFF

49

ON

OFF

OFF

OFF

ON

ON

OFF

OFF

50

OFF

ON

OFF

OFF

ON

ON

OFF

OFF

51

ON

ON

OFF

OFF

ON

ON

OFF

OFF

52

OFF

OFF

ON

OFF

ON

ON

OFF

OFF

53

ON

OFF

ON

OFF

ON

ON

OFF

OFF

54

OFF

ON

ON

OFF

ON

ON

OFF

OFF

55

ON

ON

ON

OFF

ON

ON

OFF

OFF

1-11

1-12

Page 120
Image 120
Samsung SCC-643(P) Impostazioni DI Selezione, Impostazioni di terminazione RS-422A/RS-485, RS-422A/RS-485 in duplex