Installation

CABLING

DVR/ Keyboard

RS-485

D+ D- D+ D-

Connector to the dome camera

BNC

VIDEO

Monitor

 

ALARM OUTPUT

 

1

2

3

 

4

 

ALARM INPUT

 

 

1 2 3 4 G 5

6

7

8

 

POWER

 

 

 

NC.

ENG

Power Connection

• Please, check the voltage and current capacity of rated power carefully.

Rated Power

Input Voltage Range

Current Consumption

 

 

 

AC 24V

AC 19V ~29V

2.5 A

 

 

 

RS-485 Communication

For PTZ control, connect this line to keyboard and DVR. To control multiple cameras at the same time, RS-485 communication lines of them is connected in parallel as shown below.

English – 13

Page 13
Image 13
Samsung SCC-C7478P Cabling, Power Connection, RS-485 Communication, Rated Power Input Voltage Range Current Consumption