Samsung SCC-C7478P Installation, Dip Switch Setup, Communication Protocol Setup, Camera ID Setup

Models: SCC-C7478P

1 165
Download 165 pages 31.15 Kb
Page 9
Image 9
Installation

Installation

DIP SWITCH SETUP

Communication Protocol Setup

Before you install the camera, you should set the DIP switches to confi gure the camera ID, communication protocol.

w™–›–Š–“iœˆ‹Gyˆ›Œ WŸWWGaGhœ›–Gw™–›–Š–“

ON ON

1 2 3 4 5 6 7 8

WŸWXGaGwŒ“Š–Tk
WŸWWGaGY[WW

• Select the appropriate Protocol with DIP switch

WŸWYGaGwŒ“Š–Tw

WŸWXGaG[_WW WŸWYGaG`]WW

combination.

WŸWZGaGzhtzun

WŸWZGaGX`YWW

WŸW[GaGZ_[WW

yzT[_\ {Œ™”•ˆ›Œ

pkGzŒ››•ŽGOX¥Y\\P

Camera ID Setup

ON ON

1 2 3 4 5 6 7 8

ID number of camera is set using binary number. The example is shown bellow.

Pin

1

2

3

4

5

6

7

8

 

 

 

 

 

 

 

 

 

ID Value

1

2

4

8

16

32

64

128

 

 

 

 

 

 

 

 

 

ex) ID=5

on

off

on

off

off

off

off

off

ex) ID=10

off

on

off

on

off

off

off

off

 

 

 

 

 

 

 

 

 

The range of ID is 0~255. Factory default of Camera ID is 1.

If you want to control a certain camera, you must match the camera ID with Cam ID setting of DVR or Controller.

 

Switch State

 

Protocol

Pin1

Pin2

Pin3

Pin4

 

 

 

 

 

 

OFF

OFF

OFF

OFF

Auto Protocol

 

 

 

 

 

ON

OFF

OFF

OFF

PELCO-D

 

 

 

 

 

OFF

ON

OFF

OFF

PELCO-P

 

 

 

 

 

ON

ON

OFF

OFF

SAMSUNG

 

 

 

 

 

If you set the protocol as Auto Protocol, camera will automatically recognize the kind of Protocol.

If you want to control using DVR or system keyboard, their protocol must be identical to camera. Otherwise, you can not control the camera.

If you changed camera protocol by changing DIP S/W, the change will be effective after you reboot the camera.

Factory default of protocol is “Auto” Protocol

Communication Baud rate Setup

ON ON

1 2 3 4 5 6 7 8

Select the appropriate Baud rate with DIP switch combination.

 

Switch State

 

Protocol

 

 

 

 

 

Pin5

 

Pin6

 

Pin7

 

 

 

 

 

 

 

 

 

OFF

 

OFF

 

OFF

2400 BPS

 

 

 

 

 

 

ON

 

OFF

 

OFF

4800 BPS

 

 

 

 

 

 

OFF

 

ON

 

OFF

9600 BPS

 

 

 

 

 

 

ON

 

ON

 

OFF

19200 BPS

 

 

 

 

 

 

OFF

 

OFF

 

ON

38400 BPS

 

 

 

 

 

 

• Factory default of Baud rate is “9600 BPS”