COLOR CCD CAMERA User Guide
34
COLOR CCD CAMERA User Guide
35
Operating Your Camera
SPECIAL SETUP
PRIVACY OFF
DAY/NIGHT AUTO
DIS OFF
When using a Video Auto Iris Lens, if you set the lens level to low, automatic switching
between Color and Black & White may not occur.
You cannot control the DAY/NIGHT menu when AGC in the EXPOSURE menu is ‘OFF’.
At this time, the exchange between DAY mode and NIGHT mode operates as like
selecting ‘COLOR’ mode.
The OSD key does not work for 3 seconds when switching to Color or B/W, to ensure
stable camera operation.
• The camera may focus less well under infrared illumination than under normal
illumination.
• Since the camera may not focus as well under infrared illumination at night as it does
under normal illumination, install an Extra-low Dispersion Lens to obtain sharp
pictures.
• The brightness of illumination is changeable by installed environment.
Notes
DIS : The DIS mode can compensate for vibration of the camera.
When DIS is operating, D-ZOOM does not operate.
Notes
SYNC : Two synchronization modes are available INTERNAL and EXTERNAL LINE-LOCK.
In LINE-LOCK mode, it synchronizes the camera's video out signal to the external
SYNC signal.
SPECIAL SETUP
PRIVACY OFF
DAY/NIGHT COLOR
DIS OFF
SYNC INT
COMM ADJ (Communication Adjustment) :
This function sets up the camera communication status
when controlling the camera through an external
controlled device.
When the SPECIAL menu screen is displayed, by
moving the up or down direction of the Function Setup
Switch
so that the arrow indicates ‘COMM ADJ’.
Set up the mode moving the 4 direction of Function Setup Switch.
COMMUNICATION SETUP
PROTOCOL SAMSUNG-T
CAM ID 1
BAUD RATE 9600
UART MODE 8-N-1
RET PKT DISABLE
RETURN
||||||||||||||||||||||||||
- CAM ID : Determines the camera's identification number (between 0 and 255).
- Protocol : Select the communication PROTOCOL. (SAMSUNG-T/SAMSUNG-E,
PELCO-D/PELCO-P/BOSCH/HONEYWELL/VICON/AD/PANASONIC)
- BAUD RATE : You can select 2400/4800/9600/19200/38400/57600 bps.
- UART MODE : You can select NONE, EVEN or ODD for the parity bits.
• INT : Internal synchronization
• LL : External line-lock synchronization
· If you choose 'LL', you can adjust the desired phase.
Press the SET button.
· You can adjust the desired phase from 0 to 359.