Back
AC type
DC type
Power LED
The LED turned on when power is supplied.
V. PHASE
Used to adjust vertical phase Linelock mode from 0~270
Menu Setup Switch
Used to choose the desired menu on or off, select the menu.
GND
Power ground.
Power Input Terminal
It involved power input. Use only AC 24V, UL Listed Class 2 Power Supply
Video Output Jack
Used to connect an external video monitor in jack.
DC Level
Used to adjust DC IRIS lens level. (You can adjust DC level when ESC mode is off.)
AC24V GND
Power LED
The LED turned on when power is supplied.
Menu Setup Switch
Used to choose the desired menu on or off, select the menu.
GND
Power ground.
Power Input Terminal
It involved power input.
Video Output Jack
Used to connect an external video monitor in jack.
DC Level
Used to adjust DC IRIS lens level. (You can adjust DC level when ESC mode is off.)
High Voltage Type
Iris Lens Plug | Instruction Manual |
•The image has been set for optimum performance at the factory. Do not remove the cover unless it is absolutely necessary.
It could cause damage to components and problems.
10 | COLOR CCD CAMERA | COLOR CCD CAMERA | 11 |