English-2-18

2-6) Camera and Monitor connections
1) External terminal connecting method for CAMERA
An additional PIR sensor or external sensor can also be connected.
The additional PIR sensor can be connected as shown in the illustration above.
Sensor’s trigger signal is NO (Normal Open).
Sensor is not supplied. (Sold separately)
a. Connect the A/O (HOT) terminal on the rear panel to the Alarm IN terminal of External device.
b. Connect the A/O (COLD) terminal on the rear panel to the Ground terminal of External device.
c. Connect the A/R terminal on the rear panel to the Alarm Reset terminal of External device.
d. Connect the G (ground) terminal on the rear panel to the Ground terminal of External device.
PIR Sensor
Sensor in put
Camera alarm injack
Sensor