Sanus Systems LA112 manual HC is displayed on control box

Models: LA112

1 31
Download 31 pages 1.03 Kb
Page 27
Image 27

Troubleshooting

continued

“HC” is displayed on control box

Possible Causes:

Person or object is obstructing the motion of the X-arm™.

One of the large drive screws has dirt or something on it.

The linkages are rubbing against something.

A motor cable has a short.

How to Correct:

1. Unplug X-arm™ from power for at least 10 seconds..

2. Check that the TV and X-arm™ are not trapped against the wall or any other object.

3. Plug in X-arm™, turn on the power and try to move the X-arm™ using the remote control. If it works properly, do not continue to the next step.

4. With the X-arm™ powered on, insert the provided plastic pointer in the Selector hole on the side of the X-arm™ and press it until “t” shows on the LED display.

5. Using the remote control, straighten X-arm™ so that it is parallel with the wall, and then press the “Set” button on the control box for three seconds. The X-arm™ should return to the home position against the wall.

6. Turn the power switch on the control box to “0” (OFF).

7. Hold down the Set button on the control box while switching the power switch to “1” (ON). Continue holding down the Set button for 5 seconds until the display reads CT.

8. Stand back while X-arm™ moves through the calibration sequence, moving in and out, left and right and up and down.

9. X-arm™ is done calibrating when it goes back to the home position against the wall.

10. Turn on the X-arm™ and test to see if it is operating normally. If it is not, remove the TV from X-arm™ and continue.

11. Check that there are no foreign objects in the switches and motors in the areas shown in the picture.

12. Check to see that the wire connections are securely connected and clean any substances that are found around the large drive screws.

13. Check the motors for faults in the areas shown in the picture.

14. Plug in X-arm™. Turn on the power, and try to move X-arm™ using the remote control.

Power Switch

Control Box

LED Display

Selector

Set Button

HC Error

switch

motor

motor

switch

switch

motor

6901-100189 <01>

Page 27
Image 27
Sanus Systems LA112 manual HC is displayed on control box