Lamp mode

This Projector is equipped with 2 Projection Lamps and the number of using lamps can be switched to 2 lamps or 1 lamp. Using 1 lamp maintains the life of Projection Lamps.

To change over Lamp Mode

Set "2 lamps mode" or "1 lamp mode" by pressing the Point 7 8 buttons. When the Lamp Mode is switched from "2 lamps mode" to "1 lamp mode", the image becomes a little darker. When the Lamp Mode is switched from "1 lamp mode" to "2 lamps mode", the image becomes brighter gradually.

Note:

When neither of the two lamps is lighted, the projector will shutdown automatically.

When either of the two lamps does not light up, the LAMP 1/2 REPLACE indicator blinks orange and the projector will light the other automatically.

After changing the Lamp Mode, it cannot be switched again for 90 seconds.

Lamp control

This function allows you to change the brightness of the screen.

Auto . . . . . Brightness according to the input signal.

Normal . . . Normal brightness.

Eco . . . . . . Lower brightness. Lower brightness reduces the lamp power consumption and extends the lamp life.

Filter control

You can replace the filter with this function. Press the SELECT button at Filter control to display a confirmation box. To replace, press the SELECT button at “YES” and the electrically operated filter starts to scroll.

You can also replace the filter by using the remote control (p. 30).

Fan control

Choose the running speed of cooling fans from the following

options.

 

Normal

Normal speed.

Max

Faster than the normal speed.

Note:

Filter replacement icon and “Please wait...” message appear on the screen when the filter is being scrolled.

The filter cannot be rewound.

When the filter is replaced, the total accumulated time of the filter use is automatically set to 0.