Maintenance and Cleaning

Lamp Replacement

When the life of the projection lamp of this projector

TOP CONTROL

draws to an end, the LAMP REPLACE indicator emits

 

a yellow light. If this indicator lights yellow, replace the

 

lamp with a new one promptly.

 

WARNING:

 

TURN OFF THE UV LAMP BEFORE

 

 OPENING THE LAMP COVER

 

T h i s i n d i c a t o r i s yellow when the life of the projection lamp draws to an end.

CAUTION

CAUTION

Allow a projector to cool, for at least 45 minutes before you open the Lamp cover. The inside of the projector can become very hot.

For continued safety, replace with a lamp of the same type. Do not drop a lamp or touch a glass bulb! The glass can shatter and may cause injury.

Follow these steps to replace the lamp.

1 Turn off the projector and disconnect the AC power cord. Allow the projector to cool for at least 45 minutes.

2

Loosen the screw with a screwdriver, and remove

3

the lamp cover.

Loosen the 3 screws of the lamp with a screwdriver

 

and lift the lamp out of the projector by using the

4

built in handles.

Replace the lamp with a new one and secure it

 

with the 3 screws. Make sure that the lamp is set

 

properly. Replace the lamp cover and tighten the

 

screw.

5

Connect the AC power cord to the projector and

6

turn on the projector.

Reset the lamp replacement counter..

 

See "Lamp Replacement Counter" on the next

 

page .

Lamp Cover

Screw

Screw

Lamp Screw

Screw

Handles

ORDER REPLACEMENT LAMP

Replacement lamp can be ordered through your dealer. When ordering a projection lamp, give the following information to the dealer.

Model No. of your projector

: PLC-XW50/PLC-XW55

Replacement Lamp Type No.

: POA-LMP107

 

(Service Parts No. 610 330 4564)