REPLACING A POWER SUPPLY FUSE

The rear of the matrix bay provides a separate power input receptacle for each power supply. Each power input receptacle is equipped with a fuse holder (refer to Figure 33). Each fuse holder provides a spare fuse to be used when replacing a blown fuse.

WARNING: Failure to replace a fuse with a fuse of the same rating can result in serious damage to the matrix bay. To replace the fuse in a power supply, do the following:

1.Remove the power cord from the power input receptacle.

2.Using a small screwdriver, pry the fuse holder out of the socket. The fuse holder comes out of the unit.

3.Replace the fuse with a fuse of the same rating. If using the spare fuse, be sure to replace it with a fuse of the same rating.

4.Install the fuse holder back into the socket.

5.Plug the power cord into the power input receptacle.