INSTALLING OR REPLACING A CM9760-DFL DOWNFRAME LOOPING CARD
The
•In a
•In a
If necessary, a
Installing a CM9760-DFL Card
WARNINGS:
•Rear panel card installation should be performed by qualified personnel only.
•Electrostatic discharge (ESD) precautions must be observed when installing a rear panel card. Always wear a grounding strap connected to an approved grounding source when working on or near exposed electronic equipment.
NOTE: When a
To install a
1.Set termination jumpers
•When looping to another device is required, set the jumpers in the unterminated position (jumper positions 2 and 3). Termination must occur at the final device.
•When looping is not required, set the jumpers in the terminated position (jumper positions 1 and 2).
UNTERMINATED TERMINATED
Figure 24. Termination Jumpers on CM9760-DFL Card
2.Locate the desired slot position at the rear of the bay.
3.Remove the blank cover plate by loosening the screw at the top and bottom of the plate.
C1572M (9/05) | 41 |