Adjusting System Time in a Multi-Node System

To adjust system time in a multi-node system, do the following:

1.Wait 24 hours—or a multiple of 24 hours if necessary—since the system time was set, and then compare the system time displayed on any monitor in the system with the RTC time. Note the difference in time for a 24-hour period and whether the system time is ahead of or behind RTC time. For example, if system time is 2:02.30 PM and RTC time is 2 PM after a 24-hour period, then system time is ahead of RTC time by 2 minutes and 30 seconds.

If the amount of time over which you are comparing system time to RTC time is a multiple of 24 hours, perform steps a-c that follow to determine the difference in time per 24-hour period; otherwise, proceed to step 2.

a.Convert the time difference noted between system time and RTC time to seconds.

b.Divide the total number of seconds by the elapsed time in hours to determine the seconds per hour rate of change. For example, if a 90-second time difference had occurred over a time interval of 3 days or 72 hours, then the rate of change in seconds per hour is 1.25 (90 divided by 72 = 1.25).

c.Multiply the seconds per hour rate of change by 24 to obtain the time difference in seconds for a 24-hour period. For example, multiplying 1.25 by 24 equals a time difference of 30 seconds per 24-hour period.

2.Using the CM9760-KBD, set system time at the top of the hour in 24-hour format. For example, if RTC time equals 2:00 PM, enter the following:

14 00 00

3.At the CM9700-NW1 diagnostic screen, press Alt+L using the CM9700-NW1 PC keyboard. The screen provides a display similar to the following:

**********TIME ADJUSTMENT*********

Last Time

Adjustment

0:0.0

Total Time

Adjustment

0:0.0

Format Example

 

 

 

 

+10:20.5

Adds

10

min

20.5 seconds per day

-5:10.61

Subtracts 5

min

10.61 seconds per day

***********ESC TO CANCEL********** =>

4.At the => system prompt, enter the time difference noted in step 1 in the following format: –mm.ss.hh or mm:ss.hh

where:

– = minus sign. A minus sign must be entered if system time is ahead of RTC time and must be slowed for synchronization with RTC time.

mm = minutes

ss = seconds

hh = hundredths of a second

For example, to enter the time difference of 2 minutes and 30 seconds noted in step 1 in order to slow system time over the next 24 hours, enter the following:

–02:30.00

C1572M (9/05)