Table P. ASCII Command Descriptions (Continued)
Action | Command* |
| Command Description |
|
|
|
|
|
| Camera Control Commands | |
|
|
|
|
Focus Near | Na |
| Causes the currently selected camera to adjust the focus range |
|
|
| nearer to the camera. |
Stop Focus Near | ~Na |
| Stops the focusing of the currently selected camera. |
|
|
|
|
Focus Far | Fa |
| Causes the currently selected camera to adjust the focus range |
|
|
| farther from the camera. |
Stop Focus Far | ~Fa |
| Stops the focusing of the currently selected camera. |
|
|
|
|
Iris Open | Oa |
| Opens the iris of the currently selected camera and brightens |
|
|
| the image. |
Stop Iris Open | ~Oa |
| Stops opening the iris of the currently selected camera. |
|
|
|
|
Iris Close | Ca |
| Closes the iris of the currently selected camera and darkens the |
|
|
| image. |
Stop Iris Close | ~Ca |
| Stops closing the iris of the currently selected camera. |
|
|
|
|
Zoom Telephoto | Ta |
| Narrows the field of view of the currently selected camera and |
|
|
| makes objects appear larger (zooms in). |
Stop Zoom Telephoto | ~Ta |
| Stops the currently selected camera from zooming in. |
|
|
|
|
Zoom Wide | Wa |
| Widens the field of view of the currently selected camera and |
|
|
| makes objects appear smaller (zooms out). |
Stop Zoom Wide | ~Wa |
| Stops the currently selected camera from zooming out. |
|
|
|
|
|
| Advanced Commands | |
|
|
|
|
Start Record Pattern |
|
| On receivers that do patterns, the Start Record Pattern |
|
|
| command allows recording of a |
|
|
| ranging from 1 to 99 equals the pattern number. (Consult the |
|
|
| receiver manual for specific information regarding |
|
|
| implementation.) |
Stop Record Pattern |
|
| Stops the recording of a pattern. |
|
|
| NOTE: The Start Record Pattern command functions as a |
|
|
| toggle. Issuing the |
|
|
| pattern. Issuing the command a second time stops recording |
|
|
| the pattern. |
|
|
| NOTE: In some instances, entering the pattern number as part |
|
|
| of the command is optional. For example, Spectra II™ and the |
|
|
| ES3000 Series Esprit™ units are capable of recording one full |
|
|
| pattern or two |
|
|
| |
|
|
| pattern recording. |
|
|
| sequence, except that the pattern number must be included in |
|
|
| the command to start and stop pattern recording. |
|
|
|
|
Start Pattern |
|
| Starts the pattern. A value ranging from 1 to 99 equals the |
|
|
| pattern number. (Consult the receiver manual for specific infor- |
|
|
| mation regarding implementation.) |
Stop Pattern |
| Stops the pattern. | |
|
|
|
|