Table B. RS-422 SERCOM Port Connections in a Single-Node System without a CM9760-HS Hot Switch

Device

SERCOM Port Connection

CM9700-MGR Device Tree Port Assignments

 

 

 

CM9760-MXB(s)

Port 5 and next sequential ports as necessary

 

 

 

 

Other devices

Any available ports—connections do not have

 

 

to be in sequential ports

 

 

 

 

Table C. SERCOM Port Connections in a Networked System with a CM9760-HS Hot Switch

 

 

 

Device

SERCOM Port Connection

CM9700-MGR Device Tree Port Assignments

 

 

 

CM9760-HS

Port 5

 

 

 

 

CM9700-NW1

Port 6—connected through the hot switch

 

network interface unit

 

 

 

 

 

Matrix bay(s)

Port 7 and next sequential ports as necessary—

 

 

connected through the hot switch

 

 

 

 

Other devices

Any available ports connected through the hot

 

 

switch—connections do not have to be in

 

 

sequential ports

 

 

 

 

Table D. SERCOM Port Connections in a Networked System without a CM9760-HS Hot Switch

 

 

 

Device

SERCOM Port Connection

CM9700-MGR Device Tree Port Assignments

 

 

 

CM9700-NW1 network

Port 5 on each CM9700-CC1 in the network

 

interface unit

 

 

 

 

 

Matrix bay(s)

Port 6 and next sequential ports as necessary

 

 

 

 

Other devices

Any available ports—connections do not have

 

 

to be in sequential ports

 

 

 

 

NOTE: If you add matrix bays to an existing system, you may need to change existing port connections to be able to connect each additional matrix bay to the lowest sequential port possible.

Connecting Power to the CM9700-CC1

To connect power to the CM9700-CC1, connect the supplied 120 VAC or 230 VAC power cord to the power input receptacle on the CM9700-CC1 and to an approved power source.

NOTE: Do not power on the CM9700-CC1 until all system devices have been connected to the CM9700-CC1 and all system devices have been powered on.

20

C1572M (9/05)

Page 20
Image 20
Pelco System 9760 manual Connecting Power to the CM9700-CC1, CM9760-HS Port CM9700-NW1, Interface unit Matrix bays