ENTERING CM9700-CC1 PC KEYBOARD COMMANDS

Using the PC keyboard connected to the AT-compatible keyboard port of the CM9700-CC1, you can enter commands to perform certain functions or to obtain system status information in the System box on the diagnostic screen. Refer to Table J for a list of CM9700-CC1 functions and associated PC keyboard commands.

Table J. CM9700-CC1 PC Keyboard Command Functions

Function

Keyboard Command

System Box Display Message

 

 

 

Allocate monitor box 1 to 8 on diagnostic screen

Function key F1 to F8,

Example: Pressing F1 to allocate monitor box 1 results in

 

which correspond to

the following message:

 

monitor box 1 to 8,

Allocate Box 1 to ?

 

respectively

(Refer to the Allocating Monitors to Monitor Boxes

 

 

section for additional information.)

 

 

 

Stop system operation

Ctrl+Q

Exit to DOS prompt

 

 

NOTE: When Ctrl+Q is entered, the 9760 system

 

 

stops operating and the C:\9700 prompt appears.

 

 

The CM9760-KBDs go offline and the time and date

 

 

titling on the monitor outputs from the CM9760-MXB

 

 

stop at XX:XX:59. Operators then lose control of the

 

 

system. It is recommended that system operation be

 

 

stopped during off-peak hours if possible.

 

 

 

Display number of messages to be printed

Alt+O

Total Ptr Msg => 0

 

 

NOTE: Printer port is reserved for future use.

 

 

 

Display port parameters

Alt+A

Example: 1 - ATNRQ (IRQ 10) Connected to SER1

 

 

NOTE: Toggling the Alt+A key combination cycles

 

 

through all allocated IRQs and associated connections

 

 

as configured.

 

 

 

Display operator logged-on parameters

Alt+J

Example: LogOn–Opr1, KB2,Pin1111,Port 7,index2

 

 

NOTE: Toggling the Alt+J key combination cycles

 

 

through operators.

 

 

 

Display system alarm parameters

Alt+K

Example: Sys:3 Auto:0 1

 

 

 

 

Alt+Z

Example: (10,0) (10,0) (10,0) (10,0)

 

 

 

Display/set time adjustment parameters

Alt+L

Last Adj. 0 : 0. 0 Total 0: 0 . 0

 

 

(Refer to the System Programming Using DOS section

 

 

for detailed information about setting and adjusting

 

 

time in a single-node system.)

 

 

 

 

Shift+ESC

Last Adj. 0 : 0. 0 Total 0: 0 . 0.60

 

 

NOTE: The Shift+ESC command must follow the Alt+L

 

 

command.

 

 

 

Display operator alarm parameters

Alt+C

Example: Kb2 Alms 0 Alarm 0 0 0 0 FI0 0 0

 

 

 

Display alarm sequence parameters

Alt+B

Cur0, Alms0-0 0 0 0 Cams0-0 0 0 0

 

 

 

Display configuration filename

Alt+N

Example: Configuration file is NODE1

 

 

 

Display number of peripheral devices connected to the

Alt+V

Example: Port10 Node1 NIU0 Cam16 Mon8 Kbd11

system

 

NOTE: Continue toggling for entire list of peripheral

 

 

devices.

 

 

 

Toggle printer port on/off

Alt+P

Printer not allocated

 

 

NOTE: Printer port is reserved for future use.

 

 

 

C1572M (9/05)

75

Page 75
Image 75
Pelco System 9760 manual Entering CM9700-CC1 PC Keyboard Commands, System Box Display Message