INSTALLING OR REPLACING A CM9760-RPL REAR PANEL LOOPING CARD
The
Installing a CM9760-RPL Card
WARNINGS:
•Rear panel card installation should be performed by qualified personnel only.
•Electrostatic discharge (ESD) precautions must be observed when installing a rear panel card. Always wear a grounding strap con- nected to an approved grounding source when working on or near exposed electronic equipment.
NOTE: A
To install a
1.Set termination jumpers
•When looping functions are required, set the jumpers in the unterminated position (positions 2 and 3).
•When looping functions are not required, set the jumpers in the terminated position (positions 1 and 2).
TERMINATED
UNTERMINATED
3 | 2 | 1 |
| ||
|
|
Figure 20. Termination Jumpers on CM9760-RPL Card
2.Locate the desired slot position at the rear of the bay.
NOTE: In a bay that is to be fully populated with
The corresponding CM9760-VCC cards must also occupy odd slot positions.
C1572M (9/05) | 37 |