Section 4. Programming Reference

Print Darkness

Command Structure <ESC>#Eab

 

a

=

Print Darkness Range (A thru F)

 

b

=

Print darkness value (1 thru 5)

 

Example:

<ESC>#E2A

 

Placement: Must be placed immediately after <ESC>A and

 

 

 

immediately before <ESC>Z in its own separate data stream

 

Default:

Value set in printer using the <ESC>PG Printer Setting

Command Function

To specify a new print darkness setting. This command allows

 

software control of the darkness setting for unique media and ribbon

 

combinations.

Input to Printer

<ESC>A

 

 

<ESC>#EA2

 

 

<ESC>Z

 

Printer Output

There is no printer output for this command.

Special Notes

1. This becomes the new setting in the printer configuration for all

 

 

subsequent print jobs, unless changed. The setting is stored in

 

 

non-volatile memory and is not affected by cycling power.

2. The allowable Print Darkness Level setting is “A” for SATO ThechoTherm direct thermal media and “B” for SATO TechnoTherm coated thermal transfer media.