OPERATOR PANEL
The Operator Panel consists of three LED indicators and three switches.
POWER Green LED, illuminated when power is applied.
ERROR Red LED, illuminated when there is a system fault
such as an open print head.
ON LINE Green LED, illuminated when the printer is ON LINE
and ready to receive data. The printer is placed ON
LINE and OFF LINE by toggling the ON LINE key.
ON LINE KEY If the ONLINE LED is illuminated, pressing this switch
will place the printer in the OFFLINE mode. Pressing
the switch again will place the printer back in the
ONLINE mode. If this switch is pressed while the
printer is printing, the printing process is suspended.
To resume printing, press this switch again. When the
printer is ON LINE, it is ready to receive data from the
host. When it is OFF LINE, the printer will not receive
data from the host or print.
FEED KEY Feeds one label when pressed in the OFFLINE mode.
If this switch is held in the depressed position while
power is applied, a printer status label will be printed.
POWER A two position switch that applies power to the printer.
When the “0" position is pressed, power is removed
from the printer. When the ”1" position is pressed,
power is applied to the printer.
POWER
LED
ON LINE
LED
ON LINE
Key
FEED
Key
POWER
Switch
ERROR
LED
Section 2. Installation and Configuration