Appendix BTroubleshooting

This LCD monitor comes pre-adjusted with standard VGA timing. Due to output timing differences among various VGA cards, you may initially experience an unstable or unclear display when a new display mode or new VGA card is selected.

Before applying any of the following troubleshooting procedures, you should first apply the Auto Adjust option in the OSD menu.

Problem

Possible solutions

 

 

Display is unclear and

To stabilize and clarify your display, open the OSD and

unstable

adjust the clock and phase to obtain a clear display or change

 

the resolution to the display’s optimal setting 1680 x 1050 at

 

60Hz. Make sure you use auto adjust function after

 

changing the resolution.

 

 

There is no LCD

If there is no display on the LCD, refer to the following:

display

1. Make sure that the power indicator on the LCD monitor is

 

lit, that all connections are secure, and that the system is

 

running on the correct timing. Refer to Appendix A for

 

information on timing.

 

2. Turn off the LCD monitor and then turn it back on again.

 

Press the OSD Menu button (refer to Chapter 2) once and

 

then press one of the Adjustment Control buttons several

 

times. If there is still no display, press the other

 

Adjustment Control button several times.

 

3. If step 2 does not work, connect your PC system to another

 

external CRT. If your PC system functions properly with

 

a CRT monitor but it does not function with the LCD

 

monitor, and the LCD monitor’s power LED is blinking,

 

the output timing of the PC’s VGA card may be out of the

 

 

Page40

SCEPTRE X22

Page 40
Image 40
Sceptre Technologies SCEPTRE X22 specifications Appendix B-Troubleshooting, Problem Possible solutions