9.At the C:\ > prompt, enter: nwsetup

63230-216-207/A3

Chapter 5—Setup

9/2002

Configuring the Power Server Communication Connection

 

 

9.At the C:\ > prompt, enter: nwsetup

The PowerLogic Network Setup Application displays in HyperTerminal.

30703014

NOTE: Even if the Power Server will not be used in a networked environment, you must run the Network Setup application at least once and then type 5 to quit.

10.Set all of the network setup options as described in Table 1.

NOTE: To change any of the options, enter the option number at the Enter Option prompt and press Enter.

11.Follow the onscreen instructions to change the value.

Table 1: Power Server Setup—HyperTerminal Options

Option

Description

 

The computer name defaults to the MAC Address. We

 

recommend that you leave the default computer name. If

Computer Name

you must change the name, it must be a unique alpha-

 

numeric name, limited to 15 characters, no spaces or

 

special characters.

 

 

IP Address 1

Use IP Address 1 as the primary address to access all the

capabilities of the Power Server.

Subnet Mask 1

Subnet Mask 1 is assigned to IP Address 1.

 

 

 

IP Address 2

IP Address 2 and Subnet Mask 2 are optional. They should

Subnet Mask 2

only be used if slave Modbus/Jbus and PowerLogic devices

(optional)

need to have the same address on both COM 3 and COM 4.

 

 

Router Address

Address of your company’s Ethernet LAN router, if

applicable.

 

 

 

MAC Address

Unique media access control number (cannot be changed).

 

 

12.After changing the options verify that all settings are correct.

13.At the Enter Option prompt, type 5 to quit. The Power Server reboots automatically.

NOTE: It can take approximately five minutes to reboot. If errors occur, review all configuration settings before exiting HyperTerminal.

14.Exit HyperTerminal.