28 Hawk 1LP Family Installation Guide, Rev. D
J2
Jumper
Position Jumper Function Description
RES |
| |
Off/On | Reserved. Default is no jumper installed. | |
DS ME |
| |
Off | Off | Spindle starts immediately after power up - De- |
|
| fault setting. |
Off | On | Drive spindle does not start until Start Unit com- |
|
| mand received from host. |
On | Off | Spindle Startup is delayed by SCSI ID times 12 |
|
| seconds after power is applied, i.e., drive 0 |
|
| spindle starts immediately when DC power con- |
|
| nected, drive 1 starts after 12 second delay, drive |
|
| 2 starts after 24 second delay, etc. |
On | On | Drive spindle starts when Start Unit command |
|
| received from host. Delayed start feature is over- |
|
| ridden and does not apply when ME jumper is |
|
| installed. |
WP |
|
|
On |
| Entire drive is write protected. |
Off |
| Drive is not write protected. Default is no WP |
|
| jumper installed. |