Barracuda 36ES2 Product Manual, Rev. B | 27 |
6.4.2Relative humidity
The values below assume that no condensation on the drive occurs.
a.Operating
5% to 90%
b.
5% to 95%
6.4.3Effective altitude (sea level)
a.Operating
b.
6.4.4Shock and vibration
Shock and vibration limits specified in this document are measured directly on the drive chassis. If the drive is installed in an enclosure to which the stated shock and/or vibration criteria is applied, resonances may occur internally to the enclosure resulting in drive movement in excess of the stated limits. If this situation is apparent, it may be necessary to modify the enclosure to minimize drive movement.
The limits of shock and vibration defined within this document are specified with the drive mounted by any of the four methods shown in Figure 7, and in accordance with the restrictions of Section 8.3. Orientation of the side nearest the LED may be up or down.
6.4.4.1Shock
a.
The drive, as installed for normal operation, shall operate error free while subjected to intermittent shock not exceeding 63 Gs at a maximum duration of 2 msec (half sinewave). Shock may be applied in the X, Y, or Z axis.
b.
The limits of
The drive subjected to
The drive subjected to a
c.Packaged
Disc drives shipped as loose load (not palletized) general freight will be packaged to withstand drops from heights as defined in the table below. For additional details refer to Seagate specifications
Package size | Packaged/product weight | Drop height |
<600 cu in (<9,800 cu cm) | Any | 60 in (1524 mm) |
48 in (1219 mm) | ||
>1800 cu in (>19,700 cu cm) | 42 in (1067 mm) | |
>600 cu in (>9,800 cu cm) | 36 in (914 mm) |
Drives packaged in single or multipacks with a gross weight of 20 pounds (8.95 kg) or less by Seagate for general freight shipment shall withstand a drop test from 48 inches (1,070 mm) against a concrete floor or equivalent.